20
DHOLLANDIA
7
RESET button: reset button for the safety PLC. Must be
pushed after switching the main power switch [1] on; or after
resetting the emergency stop [8].
8
Emergency stop: push the button to cause an immediate stop
of all electrically induced movements in case of emergency.
If equipped with a removable key, push the switch and remove
the key as long as the mobile column lift requires service or
maintenance and it should be kept out of service. The switch
can only be reset after inserting the key.
9
Light switch: turn the switch to switch the work light at the side
of the lift column on / off.
The slave column is equipped with an Emergency stop only. This
switch is mounted at the side of the oil leak tank. It is used and
operated as item [8] above.