5.9 Generator Port Use Setup Menu
5.10 Advanced Function Setup Menu
This is for Wind Turbine
DC1 for WindTurbine
V1
V2
V3
V4
V5
V6
V7
V8
V9
V10
V11
V12
0V
0V
0V
0V
0V
0V
0.0A
0.0A
0.0A
0.0A
0.0A
0.0A
0V
0V
0V
0V
0V
0V
0.0A
0.0A
0.0A
0.0A
0.0A
0.0A
DC2 for WindTurbine
Advanced Function
Wind
Set2
- 26 -
Solar Arc Fault ON
Clear Arc_Fault
System selfcheck
BMS_Err_Stop
0S
1000W
Backup Delay
Power
Advanced Function
Func
Set1
DRM
Gen peak-shaving
Grid peak-shaving
Signal ISLAND MODE
Solar Arc Fault ON---This is only for US.
System selfcheck---Disable. this is only for factory.
Gen Peak-shaving---Enable When the power of the
generator exceeds the rated value of it, the inverter will
provide the redundant part to ensure that the generator
will not overload.
Grid Peak-shaving---Enable When the power of the grid
exceeds the set value, the inverter will provide the
redundant part to ensure that the grid power does not
exceed the set value.
DRM---For AS4777 standard
Backup Delay---Reserved
BMS_Err_Stop---When the battery BMS failed to
communicate with inverter, the inverter will stop working.
Signal island mode---when the inverter connects grid,
the ATS port will output 230Vac and it is used to cuts off
Earth-Neutral(load port N line) bond via connect external
relay. When the inverter disconnects from the grid, ATS
port voltage will be 0 and the Earth-Neutral bond keeps
on. More details, please refer to left picture.
external relay
L N
ATS
load port
Inverter
shell
Ground cable
230V
coil
closed
contact
Generator Input: use Generator
SmartLoad Output: if the SOC is up than “ON”and solar power
is high than 1000W. the inverter will open smartload.
On Grid always on: mean when have Grid, the smartload will always on.
Micro Inv Input: Inverter will open Microinverter. if the SOC is
below the“ON”and close if the SOC is up than the“OFF”.
AC Couple Fre High: If choosing“Micro Inv input”, as the
battery SOC reaches gradually setting value (OFF), During the
process, the microinverter output power will decrease linear. When
the battery SOC equals to the setting value (OFF), the system
frequency will become the setting value (AC couple Fre high)
and the Microinverter will stop working.
MI export to grid cutsoff: stop exporting power produced by the
microinverter to the grid.
Mode
OFF
ON
Generator Input
SmartLoad Output
Micro Inv Input
On Grid always on
Ml export to Grid cutoff
GEN PORT USE
52.00Hz
100%
95%
Power
Rated Power
AC Couple Fre High
500W
8000W
PORT
Set1