3.5 PV Connection
3. Then,insert AC output wires according to polarities indicated on the terminal block and
tighten terminal. Be sure to connect corresponding N wires and PE wires to related
terminals as well.
4. Make sure the wires are securely connected.
5. Appliances such as air conditioner are required at least 2-3 minutes to restart because it
is required to have enough time to balance refrigerant gas inside of circuit.If a power
shortage occurs and recovers in short time,it will cause damage to your connected
appliances.To prevent this kind of damage,please check manufacturer of air conditioner
if it is equipped with time-delay function before installation.Otherwise,this inverter will
trigger overload fault and cut off output to protect your appliance but sometimes it still
causes internal damage to the air conditioner.
Before connecting to PV modules,please install a separately DC circuit breaker between
inverter and PV modules.It is very important for system safety and efficient operation to
use appropriate cable for PV module connection.To reduce risk of injury,please use the
proper recommended cable size as below.
Be sure that AC power source is disconnected before attempting to wire it to
the unit.
To avoid any malfunction, do not connect any PV modules with possible
current leakage to the inverter. For example, grounded PV modules will
cause current leakage to the inverter. When using PV modules, please be
sure NO grounding.
Chart 3-4 Cable size
Model
3.6/5KW
Wire Size
12AWG
Cable(mm )
2
4