18
-
5.4 Max. over current protec�on device
5.5 Inverter monitoring connec�on
Inverter has the func�on of wireless remote monitoring. The inverter with Wi-Fi func�on is
equipped with Wi-Fi Plug to connect the inverter and network. Wi-Fi Plug's opera�on,
installa�on, Internet access, APP downloading and other processes are detailed in the
instruc�ons.
PC
Router
WIFI
GPRS
Web Server
Phone
Pic 5.12 Internet monitoring solu�on
In order to protect the inverter AC connec�on, it is recommended to install a circuit breaker to
prevent overcurrent. See table 5.3 below.
Rated output
voltage(V)
Inverter
Rated output
current(A)
Current for protection
device(A)
Table 5.3 Recommended current protector specifica�ons
SUN-3K-G05-P
230
20
4.3
SUN-3K-G05-P-1
230
20
4.3
SUN-4K-G05-P
230
20
SUN-5K-G05-P
230
20
SUN-6K-G05-P
230
5.8
7.2
8.7
20
SUN-7K-G05-P
230
20
10.1
SUN-8K-G05-P
230
20
11.6
SUN-10K-G05-P
230
14.5
20
SUN-9K-G05-P
230
20
13.0
SUN-12K-G05-P
230
17.4
30