Dexter Laundry WCVD Series Troubleshooting And Fault Codes Download Page 12

20Lb. non-Express: 120 Volt Wiring Schematic

12

Part # 8533-074-001 09/13

Summary of Contents for WCVD Series

Page 1: ...8533 074 001 09 13 WCVD Series OPL Washers Troubleshooting And Fault Codes Starting serial number...

Page 2: ...replace solenoid Door Switch Check for continuity through door latch switch when door closed If no continuity adjust or replace door switch Door will not open Thermoactuator Check to see if thermoactu...

Page 3: ...ontinuity check pressure switch hose for obstruction If hose okay change pressure switch Water comes in but level does not rise Drain Valve open Check these areas Drain valve blockage Drain valve moto...

Page 4: ...cross terminals 21 22 indicating pressure switch has reset to the empty posi tion If no continuity change pressure switch Machine starts and does not operate VFD Check yellow enable wires from relay P...

Page 5: ...r pressure Check for blocked or restricted water flow Check to ensure the drain valve is functioning properly This error will occur on 18 washers when water level is set for high the pressure switch i...

Page 6: ...be is clear of any blockage and the pressure switch is operating properly Check the pressure switch harness F9 The washer tub does not reach the spin target frequency within 150 seconds The wash cycle...

Page 7: ...them together or replace the motor Step 3 Check braking resistors to see if they measure the correct resistance If a resistor does not measure the proper value replace it F15 The variable frequency dr...

Page 8: ...r and test See Note Measure the incoming line voltage F20 Internal drive error Check VFD fault code before turning off power Turn the power off to the washer Wait one minute Turn the power on to the w...

Page 9: ...o the washer it must remain off for three minutes for drive to reset The washer will not operate correctly if this is done improperly This will allow most fault codes to reset that are displayed at wa...

Page 10: ...problem Reset drive CE14 Command message includes unused characters Possible controller problem Reset drive Normal operation of the VFD VFD display shows operating frequency first very quickly then c...

Page 11: ...o the drive Check VFD fault code before turning off power Check the wiring connections to the drive and motor Check the ground wiring of the drive motor and incoming connection to ensure a proper grou...

Page 12: ...20Lb non Express 120 Volt Wiring Schematic 12 Part 8533 074 001 09 13...

Page 13: ...20Lb non Express 120 Volt Wiring Diagram 13 Part 8533 074 001 09 13...

Page 14: ...20Lb Non Express 208 240V Wiring Schematic 14 Part 8533 074 001 09 13...

Page 15: ...20Lb Non Express 208 240 Volt Wiring Diagram 15 Part 8533 074 001 09 13...

Page 16: ...20Lb Express 208 240 Wiring Schematic 16 Part 8533 074 001 09 13...

Page 17: ...20Lb Express 208 240 Wiring Diagram 17 Part 8533 074 001 09 13...