![Dexter Laundry N-Series Manual Download Page 12](http://html1.mh-extra.com/html/dexter-laundry/n-series/n-series_manual_2490384012.webp)
1
Phase
3
Phase
220-240 volts, 60 Hz.
208-240 volts, 60 Hz.
3 wire plus ground
3 wire plus ground
(high
leg
must
go
on
L3)
Suggested Minimum Wire Size --12 Ga.
Fusing Requirements
Dual element time delay fuse or equivalent breaker of amperage specified below.
1 Phase/3 Phase
15 amp
When injection pump takes only signal pulses from washer
terminal
block.
1 Phase/3 Phase
20 amp
When injection pump uses washer terminal block for its power
supply as well as signal pulses.
Always disconnect electrical power to the machine before performing any adjustments or service work.
Liquid Chemical Connection
In the left rear corner of the washer is the chemical injection assembly. This is where all chemical hose
connections are made. The chemical hoses should be inserted into the round PVC pipe of 14” and a
maximum of 18” to eliminate the chemical buildup in the pipe and/or restrict water flow to the tub.
Final Check Out
After all mounting, plumbing, and electrical work is completed, the washer should be run through a cycle
and checked for water leaks and proper functioning.
WARNING
Always disconnect electrical power to the
machine before performing any adjustments
or
service.
Cycle Options
Omit All Flushes
1. Remove the cler in-line splice from the end of the orange/white wire. (This wire will
be laying loose next to the terminal strip)
2. Connect the orange/white wire to terminal #2 on the terminal strip.
Omit Hot Rinses on Rinse #1 & #2
1. Remove brown/red wire from coil of R5 relay and insulate wire.
Add Hot Rinses on Rinse #1 & Rinse #2 on Temperature Push Button
Position #3
1. Remove black jumper from back of temperature switch that connects push button
#3 N.O. (B2) to push button #4 N.O. (B1)
2. Move white/brown wire on back of temperature switch to push button #4 N.O. (B1)
Add Cold Rinses on Rinse #3, #4, & #5 on Temperature Push Button
Position #3
1. Move brown/orange wire from push button #3 Common (A2) to push button #3 N.C.
(C2).
Omit Rinse #4 All Cycles
1. Remove the clear in-line splice from the end of the gray wire. (This wire will be
laying loose next to the terminal strip)
2. Connect the gray wire to terminal #2 on the terminal strip.
22
23
Part # 8533-031-001 6/22
Part # 8533-031-001 6/22
Machine
Mounting
Installation
& Operation
Trouble-
shooting
Machine
Service
Electrical
Wiring
Parts
Data
Coin
Handling
Maintenance