![DewStop breeze easy F100-1W Installation Manual Download Page 15](http://html1.mh-extra.com/html/dewstop/breeze-easy-f100-1w/breeze-easy-f100-1w_installation-manual_2490007015.webp)
Installation
13
1.
WARNING
To avoid fire or risk of electrical shock, turn OFF power
at circuit breaker or disconnect fuse. Test the power is OFF before
you begin wiring.
2.
BEFORE YOU MOUNT THE CONTROL
(new installation) Install
the control in a 8.9 cm deep single-gang or multi-gang electrical
wall enclosure. OR (replacement of existing switch) remove
existing wall plate and switch device being replaced.
3.
ATTACH POWER WIRE AND FAN WIRE
Attach 120V AC 60Hz
3-wire power (Hot / Neutral / Ground) inside the wall enclosure
with a minimum of 15.2 cm leads. Attach fan three wire leads inside
the wall enclosure also with minimum 15.2 cm leads. If an existing
power connection is used in an existing wall enclosure you must
confirm proper AC 120V Hot / Neutral / Ground are available.
4.
CONNECT WIRING
Attach wires (as shown in FIGURE #1).
Make sure the wall enclosure, fan, and the control are properly
grounded. Make sure ground wire is securely fastened. Tighten
all ground screws or wire nuts securely. Use the proper sized wire
nut for #14 or #12 wire. Make sure to strip back the copper wire
1.6 cm and twist wire and nut clockwise.
5.
FASTEN IN WALL ENCLOSURE
Tuck wires into wall enclosure
and fasten the control to the wall enclosure with the two screws
provided (See FIGURE #2).
6.
FASTEN WALL PLATE
Attach the wall plate (See FIGURE #3).
WHITE
BLACK
RED
GROUND
120V LINE AC
CONTROL
FAN
W
ALL
ENCLOSURE
FIGURE #1
FIGURE #2
FIGURE #3