Page 17
DE-M080801E • DEWE-ORION-0824-20x • Technical Reference Manual • Printing version 1.1.2 • March 19, 2014
DEWE-ORION-0824-20x
Optional ORION-CNT2-LEMO
As an option (ORION-CNT2-LEMO) the two counters can be also wired to a 7-pin female lemo connector for
direct connection of encoders or any other counter channel source.
1
2
3
6
5
4
7
7-pin female LEMO connector
EGG1B307CLL
1: Source Bx_CNT(n)
2: Aux_Bx_CNT(n)
3: Gate Bx_CNT(n)
4: Power GND
5: +5 V (max. 500 mA)
6: +12 V (max. 500 mA)
7: In- Bx_CNT(n)
n .. channels 0 to 1 of counter board
Optional ORION-BASE-DI-ISO
Some applications require isolated digital inputs.
This can be achieved with the option ORION-
BASE-DI-ISO. All inputs are isolated from the
input to the ORION board but also isolated
between each other.
*) 12V only available on instruments! N.c. on
DEWE-5x-PCI-xx expansion systems.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Source Bx_CNT0
Gate_Bx_CNT0
Aux Bx_CNT0
Source Bx_CNT1
Gate_Bx_CNT1
Aux Bx_CNT1
-
-
-
-
-
-
-
-
-
-
-
+5 V
+12 V*
In- (DI 0)
In- (DI 1)
In- (DI 2)
In- (DI 3)
In- (DI 4)
In- (DI 5)
In- (DI 6)
In- (DI 7)
In- (DI 8)
In- (DI 9)
In- (DI 10)
In- (DI 11)
In- (DI 12)
In- (DI 13)
In- (DI 14)
In- (DI 15)
-
DGND
Bx_DI 0
Bx_DI 1
Bx_DI 2
Bx_DI 3
Bx_DI 4
Bx_DI 5
Bx_DI 6
Bx_DI 7
Bx_DI 8
Bx_DI 9
Bx_DI 10
Bx_DI 11
Bx_DI 12
Bx_DI 13
Bx_DI 14
Bx_DI 15
-
-
-
Digital
Input
Counter
Input
Optional ORION-0824-CB8-BNC
Connection box for ORION-0824-200 cards,
1 m cable length, 8 BNC for analog inputs and 8 LEDs
for sensor cable break detection, two LEMO sockets for
counters and one SUB-D-37 socket for digital I/O.