DSI-5A-D9M 

TECHNICAL REFERENCE MANUAL 

 

 

If you assume a more riskless use is not provided anymore, the system has to be rendered 
inoperative and should be protected against inadvertent operation. It is assumed that a more 
riskless operation is not possible anymore if the system is damaged obviously or causes strange 
noises. the system does not work anymore. The system has been exposed to long storage in 
adverse environments. the system has been exposed to heavy shipment strain. 

Warranty void if damages caused by disregarding this manual. For consequential damages, NO 
liability will be assumed! 

Warranty void if damage to property or persons caused by improper use or disregarding the 
safety instructions. 

Unauthorized changing or rebuilding the system is prohibited due to safety and permission 
reasons (CE). 

Be careful with voltages >25 VAC or >35 VDC! These voltages are already high enough in order to 
get a perilous electric shock by touching the wiring. 

The product heats during operation. Make sure there is adequate ventilation. Ventilation slots 
must not be covered! 

Only fuses of the specified type and nominal current may be used. The use of patched fuses is 
prohibited. 

Prevent using metal bare wires! Risk of short circuit and fire hazard! 

DO NOT use the system before, during or shortly after a thunderstorm (risk of lightning and high 
energy over-voltage). An advanced range of application under certain conditions is allowed with 
therefore designed products only. For details please refer to the specifications. 

Make sure that your hands, shoes, clothes, the floor, the system or measuring leads, integrated 
circuits and so on, are dry. 

DO NOT use the system in rooms with flammable gases, fumes or dust or in adverse 
environmental conditions. 

Avoid operation in the immediate vicinity of high magnetic or electromagnetic fields, 
transmitting antennas or high-frequency generators, for exact values please refer to enclosed 
specifications. 

Use measurement leads or measurement accessories aligned with the specification of the 
system only. Fire hazard in case of overload! 

Do not switch on the system after transporting it from a cold into a warm room and vice versa. 
The thereby created condensation may damage your system. Acclimatise the system unpowered 
to room temperature. 

Do not disassemble the system! There is a high risk of getting a perilous electric shock. 
Capacitors still might be charged, even if the system has been removed from the power supply. 

The electrical installations and equipment in industrial facilities must be observed by the security 
regulations and insurance institutions. 

The use of the measuring system in schools and other training facilities must be observed by 
skilled personnel. 

The measuring systems are not designed for use in humans and animals. 

Please contact a professional if you have doubts about the method of operation, safety or the 
connection of the system. 

Please be careful with the product. Shocks, hits and dropping it from already-  lower level may 
damage your system. 

Please also consider the detailed technical reference manual as well as the security advice of the 
connected systems. 

This product has left the factory in safety-related flawlessness and in proper condition. In order to 
maintain this condition and guarantee safety use, the user has to consider the security advice 
and warnings in this manual. 

DSI-5A-D9M V20-1

15/17   

Summary of Contents for DSI-5A-D9M

Page 1: ...DSI 5A D9M ADAPTER TECHNICAL REFERENCE MANUAL DSI 5A D9M V20 1 1...

Page 2: ...TEDS sensor support 8 6 1 1 Manual operation 9 7 Warranty information 11 7 1 Calibration 11 7 2 Support 11 7 3 Service repair 11 7 4 Restricted Rights 11 7 5 Copyright 12 7 6 Trademarks 12 8 Safety i...

Page 3: ...bols and formats will be used throughout the document Important It gives you important information about the subject Please read carefully Hint It gives you a hint or provides additional information a...

Page 4: ...ous 1 Pulse load 25 00A 5 0sec 120sec interval continuous Shunt resistor 10 0m Resistance Tolerance Calibrated to 0 1 calibration in TEDS Temperature Coefficient 30ppm C typical 20 C to 60 C Resistor...

Page 5: ...connector pinout Wire connector 3pin plug Illustration 1 3 pin plug Illustration 2 The illustration shows a 10 position version of the plug DSI 5A D9M V20 1 5 17 Pin Name I O Description 1 I Power Cur...

Page 6: ...e be safe Warning Use DSI 5A D9M adapter only with SIRIUSi Isolated version DSI 5A D9M V20 1 6 17 Pin Name I O Description 1 OE I Power Output enable 2 Out O Signal Signal Output 3 OEsns I Power Outpu...

Page 7: ...xc Voltage Illustration 5 DSI 5A D9M Adapter partial schematic 6 Operation Illustration 4 DSI 5A D9M Adapter Signal output enable indicator LED is turned ON green when output signal is present on the...

Page 8: ...DSI 5A D9M TECHNICAL REFERENCE MANUAL Illustration 6 Setting Hardware setup Illustration 7 DSI adapters TEDS sensors checkbox DSI 5A D9M V20 1 8 17...

Page 9: ...is recognized and set automatically 6 1 1 Manual operation If DSI adapters TEDS sensors are left unchecked under Hardware setup then sensor supply and range has to be set manually Illustration 9 DSI...

Page 10: ...Channel setup for channel N set Excitation voltage to 15V Signal Output Enable indicator LED will be turned on to indicate that measured signal is present on the signal outputs Illustration 10 Excita...

Page 11: ...needs to be calibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed cal...

Page 12: ...ucts and we take care that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark Product families KRYPTON SIRIUS DSI DS NET and...

Page 13: ...equirements All accessories shown in this document are available as an option and will not be shipped as standard parts 8 2 1 Environmental Considerations Information about the environmental impact of...

Page 14: ...having a protective earth terminal a non interruptible safety earth ground must be provided from the mains power source to the product input wiring terminals Please note the characteristics and indica...

Page 15: ...ing leads integrated circuits and so on are dry DO NOT use the system in rooms with flammable gases fumes or dust or in adverse environmental conditions Avoid operation in the immediate vicinity of hi...

Page 16: ...ons in IEC 61000 6 2 or defined in 3 7 of IEC 61326 1 Equipment and systems intended for use in other electromagnetic environments for example in the process industry or in environments with potential...

Page 17: ...Version DSI 5A D9M V20 1 17 17 Doc Version Date dd mm yyyy Notes 0 9 09 05 2014 Pre release version 1 0 21 05 2014 Initial version amended electrical specs new safety instructions new schematic V20 1...

Reviews: