Restriction of Hazardous Substances 
This product has been classified as Monitoring and Control equipment and is outside the scope of the 
2002/95/EC RoHS Directive. However, we take care of our environment and the product is lead-free. 

8.2.4. General safety and hazard warnings for all Dewesoft systems 

Safety of the operator and the unit depend on following these rules. 

Use this system under the terms of the specifications only to avoid any possible danger. 

Read your manual before operating the system. 

Observe local laws when using the instrument. 

DO NOT touch internal wiring! 

DO NOT use higher supply voltage than specified! 

Use only original plugs and cables for harnessing. 

You may not connect higher voltages than rated to any connectors. 

The power cable and connector serve as Power-Breaker. The cable must not exceed 3 meters, 
the disconnect function must be possible without tools. 

Maintenance must be executed by qualified staff only. 

During the use of the system, it might be possible to access other parts of a more comprehensive 
system. Please read and follow the safety instructions provided in the manuals of all other 
components regarding warning and security advice for using the system. 

With this product, only use the power cable delivered or defined for the host country. 

DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a 
voltage supply unit. 

Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth 
terminal), a non-interruptible safety earth ground must be provided from the mains power 
source to the product input wiring terminals. 

Please note the characteristics and indicators on the system to avoid fire or electric shocks. 
Before connecting the system, please read the corresponding specifications in the product 
manual carefully. 

The inputs must not, unless otherwise noted (CATx identification), be connected to the main 
circuit of category II, III and IV. 

The power cord separates the system from the power supply. Do not block the power cord, since 
it has to be accessible for the users. 

DO NOT use the system if equipment covers or shields are removed. 

If you assume the system is damaged, get it examined by authorized personnel only. 

Adverse environmental conditions are moisture or high humidity, dust, flammable gases, fumes 
or dissolver thunderstorm or thunderstorm conditions (except assembly PNA) electrostatic fields, 
etc. 

The measurement category can be adjusted depending on module configuration. 

Any other use than described above may damage your system and is attended with dangers like 
short-circuiting, fire or electric shocks. 

The whole system must not be changed, rebuilt or opened. 

DO NOT operate damaged equipment: Whenever it is possible that the safety protection 
features built into this product have been impaired, either through physical damage, excessive 
moisture, or any other reason, REMOVE POWER and do not use the product until the safe 
operation can be verified by service-trained personnel. If necessary, return the product to 
Dewesoft sales and service office for service and repair to ensure that safety features are 
maintained. 

DSI-5A-D9M V20-1

14/17   

Summary of Contents for DSI-5A-D9M

Page 1: ...DSI 5A D9M ADAPTER TECHNICAL REFERENCE MANUAL DSI 5A D9M V20 1 1...

Page 2: ...TEDS sensor support 8 6 1 1 Manual operation 9 7 Warranty information 11 7 1 Calibration 11 7 2 Support 11 7 3 Service repair 11 7 4 Restricted Rights 11 7 5 Copyright 12 7 6 Trademarks 12 8 Safety i...

Page 3: ...bols and formats will be used throughout the document Important It gives you important information about the subject Please read carefully Hint It gives you a hint or provides additional information a...

Page 4: ...ous 1 Pulse load 25 00A 5 0sec 120sec interval continuous Shunt resistor 10 0m Resistance Tolerance Calibrated to 0 1 calibration in TEDS Temperature Coefficient 30ppm C typical 20 C to 60 C Resistor...

Page 5: ...connector pinout Wire connector 3pin plug Illustration 1 3 pin plug Illustration 2 The illustration shows a 10 position version of the plug DSI 5A D9M V20 1 5 17 Pin Name I O Description 1 I Power Cur...

Page 6: ...e be safe Warning Use DSI 5A D9M adapter only with SIRIUSi Isolated version DSI 5A D9M V20 1 6 17 Pin Name I O Description 1 OE I Power Output enable 2 Out O Signal Signal Output 3 OEsns I Power Outpu...

Page 7: ...xc Voltage Illustration 5 DSI 5A D9M Adapter partial schematic 6 Operation Illustration 4 DSI 5A D9M Adapter Signal output enable indicator LED is turned ON green when output signal is present on the...

Page 8: ...DSI 5A D9M TECHNICAL REFERENCE MANUAL Illustration 6 Setting Hardware setup Illustration 7 DSI adapters TEDS sensors checkbox DSI 5A D9M V20 1 8 17...

Page 9: ...is recognized and set automatically 6 1 1 Manual operation If DSI adapters TEDS sensors are left unchecked under Hardware setup then sensor supply and range has to be set manually Illustration 9 DSI...

Page 10: ...Channel setup for channel N set Excitation voltage to 15V Signal Output Enable indicator LED will be turned on to indicate that measured signal is present on the signal outputs Illustration 10 Excita...

Page 11: ...needs to be calibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed cal...

Page 12: ...ucts and we take care that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark Product families KRYPTON SIRIUS DSI DS NET and...

Page 13: ...equirements All accessories shown in this document are available as an option and will not be shipped as standard parts 8 2 1 Environmental Considerations Information about the environmental impact of...

Page 14: ...having a protective earth terminal a non interruptible safety earth ground must be provided from the mains power source to the product input wiring terminals Please note the characteristics and indica...

Page 15: ...ing leads integrated circuits and so on are dry DO NOT use the system in rooms with flammable gases fumes or dust or in adverse environmental conditions Avoid operation in the immediate vicinity of hi...

Page 16: ...ons in IEC 61000 6 2 or defined in 3 7 of IEC 61326 1 Equipment and systems intended for use in other electromagnetic environments for example in the process industry or in environments with potential...

Page 17: ...Version DSI 5A D9M V20 1 17 17 Doc Version Date dd mm yyyy Notes 0 9 09 05 2014 Pre release version 1 0 21 05 2014 Initial version amended electrical specs new safety instructions new schematic V20 1...

Reviews: