DS-CAM-600
Installation
“File types for storing” should be set to “DVI” which is uncompressed DEWESoft video
format. The CPU will not have enough power to additionally do the “live” compression.
Depending on the measurement duration, the video file can get very big.
For compression after the measurement set the appropriate compressor in “AVI file type for
compression”. We recommend downloading the XVID codec.
In Analysis mode you can then select your datafile and click “AVI compress”.
Illustration 12: AVI compress after measurement
8. Go to Ch. Setup, click the Video button, click the Unused button to enable the video
channel.
Illustration 13: DEWESoft: Channel setup > Video
HINT
Ensure the firmware version of SIRIUS hardware is at least 4.5.0.16, otherwise
please update the firmware. This is done with the “USB Firmware Upgrade
Tool” from http://www.dewesoft.com/download/section/1. Also the Firmware
File can be downloaded there. Close DEWESoft, start the Upgrade Tool, select
“DEWESoft USB” interface and firmware file and Start. After finished, it is
very important to unplug power and USB cable and reboot the SIRIUS device.
Document-Version: 1.0.0
www.dewesoft.com
Page 12/17