34
EngLIsh
Cable Removal from the Drain Cleaner and
Cable Drum Installation
WARNING:
To reduce the risk of injury, wear safety
goggles or glasses with side shields. Always wear leather
gloves with latex gloves inside. The cable is under stress
and can uncoil unexpectedly. Cable end feature may
be sharp.
Remove the cable for cleaning after each use.
To remove the cable:
1. Remove the battery pack from the tool.
2. Pull the front handle
10
out away from the tool to the
unlocked position.
3. With the tool supported vertically, remove the four screws
from the drum cover
9
.
WARNING!
The cable is under stress and can uncoil
unexpectedly. Keep pressure on the drum cover so it does
not uncoil.
4. Carefully lift the drum cover up, reach underneath to hold
the cable firmly while pulling off the drum cover
9
and
front handle
10
to expose the inner drum
12
.
5. Remove the cable from the drum cover and front handle
and tuck it into the inner drum. Set the drum cover aside.
6. Carefully remove the inner drum with cable from
the drain cleaner.
7. When cleaning the cable, carefully uncoil the cable from the
inner drum. Refer to
Cleaning
under
Maintenance
.
To install the cable:
1. Remove the battery pack from the tool.
2. Pull the front handle
10
out away from the tool to the
unlocked position.
3. Remove the four screws from the drum cover
9
.
4. Fully wind the clean, dry cable into the inner drum
12
following the cable direction symbol
14
(Fig. A).
WARNING!
Winding the cable in the wrong direction
could cause the tool to apply excessive torque causing the
cable to kink during bind up.
WARNING:
Never install a new cable by threading it
through the front handle on the tool. Always disassemble
the drum cover so you can be sure the cable is wound in
the proper direction.
5. Place the inner drum with cable back into the tool.
6. Carefully pull the cable bulb end out of the inner drum and
feed it through the front handle.
WARNING!
The cable is under stress and can unwind
unexpectedly. Keep pressure on the cable so it does
not unwind.
7. Place the drum cover and front handle over the inner drum
and reinstall the four screws. Tighten securely.
nOTE:
If the unit is unbalanced and/or vibrates
unnecessarily, the cable may be wound poorly.
OPERATION
WARNING:
Always observe the safety instructions and
applicable regulations.
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories.
An accidental
start-up can cause injury.
WARNING:
Always wear eye and other protective
equipment appropriate to the task.
WARNING:
Always wear leather work gloves with latex
gloves inside.
WARNING:
Do not operate if more than 15 cm of cable is
outside of pipe or drum.
WARNING:
The cable can whip or tangle.
WARNING:
Do not hold cable while it is turning.
WARNING:
Cable end feature may be sharp.
Proper Hand Position (Fig. D)
WARNING:
To reduce the risk of serious personal injury,
ALWAYS
use proper hand position as shown.
WARNING:
To reduce the risk of serious personal
injury,
ALWAYS
hold securely in anticipation of a
sudden reaction.
Proper hand position requires one hand on the front handle
10
,
with the other hand on the main handle
3
.
Clearing a Drain
1. Put forward/reverse control button
1
in the centre position.
2. Install the battery pack into the handle.
3. Move the forward/reverse control button
1
to the
forward position.
4. Pull the front handle
10
out into the unlock position.
5. Pull at least 46 cm (18") of the cable from the tool. Insert at
least 30 cm (12") of cable into the drain, leaving no more
than 15 cm (6") of the cable exposed.
WARNING:
Do not operate if more than 15 cm (6") of
cable is exposed. Greater distance can cause twisting,
kinking, breaking or whipping of the cable.
WARNING:
Always wear leather work gloves with
latex gloves inside when operating the drain cleaner.
WARNING:
If the cable is blocked either by the blockage
or the pipe so that the cable will not rotate, refer to the
To
Unbind Drain cleaner
section.
WARNING:
If the cable is stopped from rotating due to a
blockage or the pipe, release the trigger immediately.
WARNING:
Only operate in reverse to remove the
cable from an obstruction.
6. Continue to feed the cable out by hand into the pipe until it
becomes difficult.
Summary of Contents for XR Li-Ion DCD200
Page 1: ...DCD200 Final page size A5 148mm x 210mm ...
Page 3: ...1 Fig A Fig B 6 9 10 11 12 1 2 3 5 4 8 13 14 5 6 5 6 15 7 ...
Page 4: ...2 Fig D 4 Fig E 10 3 ...
Page 157: ...155 ...
Page 158: ...156 ...
Page 159: ...157 ...