7 Operation
26
7.9
Before starting
DANGER
Carbon monoxide.
The application of a generator in buildings can
LEAD TO DEATH WITHIN MINUTES. The exhaust fumes from the generator
contain carbon monoxide (CO). This is an invisible odorless poison. If the exhaust
fumes of the generator can be smelled, CO is being inhaled. Even if no exhaust
fumes can be smelled, CO could still be being inhaled.
1.
Read and understand the safety and operator's manual at the start of these
operating instructions.
2.
Read and understand all statements of the safety and warning signs.
3.
Check:
Engine oil level.
Fuel level.
State of the air cleaner.
Tight fit of the outer bracket.
State of the fuel lines.
7.10 Starting
See image below
1.
Disconnect all connections from the generator
2.
Open fuel shut-off valve
(a)
.
Comment
:
Close the choke
(b)
if the engine is cold (pull out)
.
Open the choke if
the engine is warm
(push).
3.
Put the engine switch in the "ON" position
(c1)
and pull the starter rope
(d)
.
Comment:
Do not start the engine if the oil level is low. In this case, check the
engine oil level and top off if necessary.
4.
Open the choke while the engine is warming up
(b)
.
5.
Put main circuit breaker in closed position
(e1)
. Allow the engine to warm up
for a few minutes before connecting electrical equipment.
b
Summary of Contents for DXGN3000E
Page 1: ......
Page 2: ...Operator s manual Portable Generator DXGN series ...
Page 48: ...Manual del operador Generador Portátil Serie DXGN ...
Page 94: ...Benutzerhandbuch Tragbarer Generator DXGN Serie ...
Page 140: ...Manuel de l opérateur Générateur portable Série DXGN ...
Page 186: ...Manuale utente Generatore portatile Serie DXGN ...
Page 232: ...Gebruikershandleiding Draagbare generator DXGN series ...
Page 278: ...Manual do operador Gerador portátil Séries DXGN ...