12
English
The air compressor MUST be bolted to a level, solid concrete
surface. Use 3/8” lag screws, vibration pads and concrete
anchors. If help is needed anchoring the air compressor consult
a licensed contractor.
1. Place the air compressor on a level, solid concrete surface.
Make sure the concrete is in good condition with no cracks
or damage.
2. Mark the surface
3/8" Lag
Screw
(not supplied)
Vibration
pad
(not
supplied)
Concrete Anchor
(not supplied)
Surface Line
Shim Under
Vibration pad
(not supplied)
using the holes in
the air compressor
feet as a template.
3. Drill holes in the
surface for the
concrete anchors.
Install concrete
anchors.
4. Line-up holes in
surface with holes
in air compressor
feet.
5. Place the vibration pads (not supplied) between the floor and
air compressor feet, see figure. If needed use shims to level
the unit.
6. Place the 3/8” lag screws through the air compressor feet,
vibration pads and into the anchors.
7. Torque 3/8” lag screws to 7-10 ft.-lbs (9.5-13.5 Nm).
Wiring Instructions
WARNING:
Improper electrical installation of this product
may void its warranty and your fire insurance. Have circuit wiring
performed by qualified personnel such as a licensed electrician
who is familiar with the current national electrical code and any
prevailing local electrical codes.
WARNING:
Risk of electrical shock. Improper electrical
grounding can result in electrical shock. The wiring should be
done by a qualified electrician.
A qualified electrician needs to knows the following before wiring:
1. The amperage rating of the electrical box should be adequate.
Refer to the air compressor's serial label for the unit's voltage
and amperage requirements.
2. The supply line should have the same electrical characteristics
(voltage, cycle, phase) as the motor.
Refer to the motor
nameplate, on side of motor, for this information.
NOTE:
The wiring used must be rated for the motor nameplate
voltage, plus or minus 10%. Refer to local codes for recommended
wire sizes, correct wire size, and maximum wire run; undersize wire
causes high amp draw and overheating to the motor.
WARNING:
Risk of electrical shock. Electrical wiring must be
located away from hot surfaces such as manifold assembly,
compressor outlet tubes, heads, or cylinders.
Grounding Instructions
This product should be connected to a metallic, permanent wiring
system, of and equipment-grounding terminal or lead on the
product.
Main power disconnect switch
Install a main power disconnect switch in the line from the panel
to the compressor. The main power disconnect switch must be
located near the compressor, for ease of use and safety. When
turned OFF, the main power disconnect switch shuts off all
power to the compressor. When it is turned ON, the compressor