Air leaks ....................................................................................................................................1
Air leaks in air tank or at air tank welds ....................................................................................2
Air leaks between head and valve plate ....................................................................................3
Air leaks from safety valve ......................................................................................................... 4
Compressor is not supplying enough air to operate accessories ............................................ 1, 5, 6, 7, 9, 10
Restricted air intake. ..................................................................................................................9
Oil in discharge air .....................................................................................................................9, 19, 31
Knocking Noise .........................................................................................................................4, 10, 11, 12, 13, 14
Excessive belt wear ...................................................................................................................10, 11, 14, 15
Squealing sound ........................................................................................................................10
Moisture in pump crankcase .....................................................................................................1, 3, 8, 17, 18, 19, 20, 21, 22
Excessive current draw .............................................................................................................14, 26, 27
Compressor won’t start in cold temperatures ..........................................................................17, 34, 35
Pressure reading on the regulated pressure gauge drops when and accessory is used .........23
Regulator knob has continuous air leak ....................................................................................24
Regulator will not shut off air outlet ..........................................................................................24
Air tank pressure will not build ..................................................................................................25
Compressor stalls ......................................................................................................................28, 29, 30
Overheating ...............................................................................................................................27, 32, 33