31
E N G L I S H
Congratulations!
You have chosen a D
E
WALT tool. Years of
experience, thorough product development and
innovation make D
E
WALT one of the most reliable
partners for professional power tool users.
Technical data
DC308 DC318
Voltage V
DC
36 28
Type
1
1
Max. power output
W
550
500
No-load speed
min
-1
0 - 2,700 0 - 2,700
Stroke length
mm
26
26
Cutting depth in:
- wood
mm
130
130
- aluminium
mm
25
25
- steel
mm
10
10
Bevel angle adjustment (l/r)
0 - 45°
0 - 45°
Weight (without battery pack) kg
2.54 2.54
L
PA
(sound pressure)
dB(A)
89
86
K
PA
(sound pressure uncertainty)
dB(A)
3
3
L
WA
(sound power)
dB(A)
98
97
K
WA
(sound power uncertainty)
dB(A)
4.3
3
Vibration total values (triax vector sum) determined according to
EN 60745:
Vibration emission value a
h
Wood
a
h
=
m/s²
4.5 4.3
Uncertainty K =
m/s²
1.7 1.5
Vibration emission value a
h
Metal
a
h
=
m/s² 5.0 6.2
Uncertainty K =
m/s²
1.8 1.5
The vibration emission level given in this information
sheet has been measured in accordance with a
standardised test given in EN 60745 and may be
used to compare one tool with another. It may be
used for a preliminary assessment of exposure.
WARNING:
The declared vibration
emission level represents the main
applications of the tool. However if the
tool is used for different applications,
with different accessories or poorly
maintained, the vibration emission may
differ. This may significantly increase the
exposure level over the total working
period.
An estimation of the level of exposure to
vibration should also take into account
the times when the tool is switched off or
when it is running but not actually doing
the job. This may significantly reduce
the exposure level over the total working
period.
Identify additional safety measures to
protect the operator from the effects of
vibration such as: maintain the tool and
the accessories, keep the hands warm,
organisation of work patterns.
Battery Pack
DE9360 DE9280
Voltage V
DC
36 28
Capacity Ah
2.2
2.2
Weight kg
1.0
.92
Charger
DE9000
Mains voltage
V
AC
230
Approx. charging time
min
60
Weight kg
0.9
Fuses:
Europe
230 V tools
10 Amperes, mains
Defi nitions: Safety Guidelines
The definitions below describe the level of severity for
each signal word. Please read the manual and pay
attention to these symbols.
DANGER:
Indicates an imminently
hazardous situation which, if not avoided,
will
result in
death or serious injury
.
WARNING:
Indicates a potentially
hazardous situation which, if not avoided,
could
result in
death or serious injury
.
CORDLESS JIGSAW
DC308, DC318
Summary of Contents for DC308
Page 1: ...www eu DC308 DC318 ...
Page 3: ...1 A 2 1 3 4 5 10 9 8 11 12 6 7 11 13 14 23 15 ...
Page 4: ...2 B D 7 6 4 C 10 8 E 16 ...
Page 5: ...3 G 8 17 19 18 16 17 20 18 22 5 21 H 2 1 1 2 F2 F1 ...
Page 6: ...4 I K J L ...
Page 174: ...172 ...
Page 175: ...173 ...