deville C07722 Instruction Manual Download Page 7

 

-7-

1.

 

GENERAL 

 

Thank you for purchasing a DEVILLE product. Read these directions carefully before handling the fireplace 

 

Fireplaces 

C07722 

are designed for use only as room heaters, they must not be used for any other purposes, for 

example as laundry dryers ! Do not cover the fireplace with anything, do not put flammable objects on - or near the 

fireplace ! Best heating result is achieved when the shutters are closed during the utilization. C07722 are powerful 

heating devices - the temperature of their metallic parts can rise to very high levels. The chimney must be done 

according to the fire safety regulations. Before starting the utilization (and after a long breaks) check out the condition 

of the chimney - is there any corrosion damage, is there draught enough. 

 

DEVILLE is not responsible for the compatibility and the quality of the other manufacturer’s products. 

 

2. TRANSPORTATION AND ASSEMBLY 

 

2.1. Transportation 

C07722 fireplace is delivered assembled. It must be carried by two persons. Handle the shutter and the surface with 

care during the transportation and assembly ! Remove the stickers from the glass shutters ! 

 

2.1.1. Stone model 

To make the transportation and installation easy and safe it is recommended that the fireplace is taken into parts 
before transportation : 

 

take away the packing, 

 

loosen the screw (total 4 pcs) from behind and front of the hood,   

 

fasten the stones with cord before hood lifting that the stones not fall to the ground, 

 

lift up the hood,  

 

take away the binding hooks from the stones and lift up the stones very carefully, 

 

protect the stones very carefully for the transportation. 

 
The installation of the fireplace : 

 

set the stand to its place leaving enough room to the backside for fixing the screws and installing the flue tube, 

 

lift the fireplace hearth onto the stand, 

 

install the stones and binding hooks. Fasten the stones with cord before hood lifting that the stones not fall to 
the ground, 

 

install the hood to its place and fix the screws, 

 

push the heater carefully to its final place. 

 

2.2. Foundation 

The foundation must be flat and steady. Take also in consideration the weight of the chimney ! 

 

2.3. Safety distances 

Negligence of current directions may cause fire 

The temperature of the fireplace’s surface can rise up to 140 °C

near the glasses - up to 350 °C. If the floor near the fireplace is made from combustible material, it must be covered, 

for example with metal sheet. The sheet must extend at least at 100 mm from the sides and 400 mm from the front of 

the shutters (fig. 1). 

 

Safety distances between the surface and constructions, made from combustible materials : 

 

- from behind : 250 mm, 

 

- upwards : 600 mm, 

 

- from both sides : 250 cm, 

 

- in front : 1000 mm. 

www.pieces-de-poele.com

Summary of Contents for C07722

Page 1: ...OELES A BOIS WOOD STOVES ESTUFAS DE LE A STUFE A LEGNA SALAMANDRAS A LENHA NOTICE D EMPLOI INSTRUCTION MANUAL GUIA DE UTILIZACION ISTRUZIONI PER L USO MANUAL DE UTILIZA O C07722 www pieces de poele co...

Page 2: ...o le auparavant enlevez l emballage d vissez les crous 4 pi ces au total l arri re et l avant de la hotte serrez les briques r fractaires avec une corde avant de soulever la hotte de mani re ce qu ell...

Page 3: ...se faire par le haut du po le et par l arri re de celui ci Quand le raccord se fait par le haut on peut galement utiliser un tuyau de raccordement non isolant les autres modules tant isolants Lisez le...

Page 4: ...fa on optimiser la combustion Il peut tre r gul par l interm diaire des r gulateurs 3 fig 4 5 l air passe travers les r gulateurs 3 fig 4 5 ce qui aide br ler le combustible rest apr s le deuxi me br...

Page 5: ...tiliser une peinture qui r siste une temp rature sup rieure 500 C 3 8 Enlever les cendres et nettoyer le foyer Pendant que votre po le fonctionne les cendres tombent dans la grille du foyer puis dans...

Page 6: ...s les d lais impartis A d faut la date figurant sur la facture mise par DEVILLE ne peut tre prise en consid ration Les interventions au titre de la garantie ne peuvent avoir pour effet de prolonger ce...

Page 7: ...arts before transportation take away the packing loosen the screw total 4 pcs from behind and front of the hood fasten the stones with cord before hood lifting that the stones not fall to the ground l...

Page 8: ...ion the safety distances 2 5 1 Connecting to the upper side all modules insulated fig 3 and 8 Attach the first module smoke damper module SP 2 After that attach the other modules of the DEVILLE module...

Page 9: ...must be totally open Adjustable fire grate fig 6 also must be totally open and the upper air flow regulator totally closed The ash shutter must be closed all the time primary air doesn t flow through...

Page 10: ...e fire grate back and forth will help the ashes to fall dawn into the box Removing the ashes and sweeping of the furnace Before starting switch of all air conditioners or fans and detach the protectiv...

Page 11: ...ed to the latter within the required time For lack of this the date on the invoice issued by DEVILLE can t be taken into account The interventions under warranty can t have the effect of continuing th...

Page 12: ...ntes de levantar la campana para que stos no se caigan levante la campana quite la cuerda de los ladrillos refractarios y lev ntelos con cuidado proteja los ladrillos durante el transporte La instalac...

Page 13: ...ared 5 fig 3 2 5 2 Conexi n con la parte superior con tubos de conexi n no aislantes fig 3 Una la junta 3 y el tubo no aislante 2 por arriba luego una el m dulo de evacuaci n de humos y el primer m du...

Page 14: ...ulaci n de la ventilaci n puede hacerse al mismo tiempo por los reguladores superiores y los reguladores secundarios Ojo con el mon xido de carbono mediante la reja del hogar y de los reguladores supe...

Page 15: ...Utilice por ejemplo un cepillo de alambre Volver a montar las piezas Para deshollinar la chimenea Si la conexi n se ha hecho por la parte superior el holl n cae por el tubo de conexi n en la estufa A...

Page 16: ...itud de reparaci n del aparato bajo garanti o bien un tal n o un volante suelto de este certificado debe seg n la organizaci n propia de DEVILLE ser devuelto a este en los plazos impartidos En su defe...

Page 17: ...los refract rios com uma corda antes de levantar o exaustor de maneira que os tijolos n o podem cair levantar o exaustor retirar a corda dos tijolos e levantar os tijolos refract rios com precau o pro...

Page 18: ...e o 1eiro m dulo isolador Fechar o evacuador de fumo da parte de tr s com a tapa 4 e o lado 5 Lembrar se que as dist ncias de seguran a entre os canos n o isolados e os elementos ambientes suscet veis...

Page 19: ...e dos reguladores de ar superiores com uma interven o sobre a qualidade ou a quantidade do combust vel N o normalmente necess rio de meter 4 troncos de lenha em mesmo tempo A lenha muito seca deve se...

Page 20: ...impeza da chamin No caso em que o juntamento est feito por a parte de cima a fuligem cai atrav s o cano de juntamento no fog o Antes de come ar pensar a soltar a parte guia da lareira www pieces de po...

Page 21: ...DEVILLE no prazo concedido Em falta desses documentos a data figurada em cima da factura emitida por DEVILLE n o pode s r presa em considera o As interven es ao titulo da garantia n o pode haver por...

Page 22: ...attoni reffrattari con una corda prima di sollevare la cappa in modo che non cadano sollevare la cappa levare la corda dai mattoni reffrattari e sollevarli con precauzione proteggere i mattoni reffrat...

Page 23: ...e Chiudere lo sfioratore di fumo posteriore utilizzando il coperchio 4 e la lastra 5 Ricordare che le distanze di sicurezza tra i tubi non isolanti e gli elementi circostanti suscettibili di bruciare...

Page 24: ...ca va utilizzata con precauzione il potere calorifico molto elevato 3 6 I vetri delle porte Uso e sostituzione fig 9 Aspettare che i vetri della stufa siano completamente freddi prima di pulirli Manip...

Page 25: ...ito a DEVILLE nei termini assegnati In mancanza di questo la data figurando sulla fattura emessa da DEVILLE non pu essere presa in considerazione Gli interventi a titolo della garanzia non possono ave...

Page 26: ...26 www pieces de poele com...

Reviews: