background image

EN

SB-2-540-J  (9/2015)

4 / 10

INSTALLATION

Important: To ensure that this 

equipment reaches you in first 

class condition, protective 

coatings have been used. Flush 

the equipment through with a 

suitable solvent before use.

1.   Attach air hose to connector (13). 

Recommended hose size 8 mm 

bore. The hose must be conductive 

and electrical bond from the 

spraygun to earth should be checked 

with an ohmeter. A resistance of less 

than 10

6

 Ohms is recommended.

2.   

Air supply should be filtered and 

regulated.

3.   Attach Cup assembly by screwing 

into the Fluid Inlet of the spraygun. 

Tighten with a wrench.

OPERATION

1.   

Mix coating material to manufac-

turers instructions.

2.   Fill the cup with the required amount 

of material. Fill to no more than 

25mm (1") from the top of the cup. 

DO NOT OVERFILL.

3.   Attach Cup Lid.  

4.   

Turn needle adjusting screw (7) 

clockwise to prevent movement. 

5.   

Turn spreader valve (5) counter-

clockwise to fully open.

6.   Adjust inlet air pressure (For recom-

mended figures see Specifications) 

at the gun inlet with the gun trig-

gered. (pressure gauge attachment 

shown under Accessories is recom-

mended for this).

7.   Turn needle adjusting screw counter 

clockwise until first thread shows.

8.   Test spray. If the finish is too dry 

reduce airflow by reducing air inlet 

pressure or by the optional Airflow 

Valve (14). Screw the Adjusting Knob 

(14) in to reduce pressure. 

9.   If finish is too wet reduce fluid flow 

by turning needle screw (7) clock-

wise. If atomization is too coarse, 

increase inlet air pressure. If too fine 

reduce inlet pressure.

10.   The pattern size can be reduced by 

turning adjusting valve (5) clock-

wise.

11.   Hold gun perpendicular to surface 

being sprayed. Arcing or tilting may 

result in uneven coating.

12.   The recommended spray distance is 

150-200 mm (6"-8").

13.  

Spray edges first. Overlap each 

stroke a minimum of 50%. Move gun 

at a constant speed.

14.  

Always turn off air supply and 

relieve pressure when gun is not in 

use.

PREVENTATIVE MAINTENANCE

1.   Turn off air and relieve  pressure in 

the supply lines, or if using QD 

system, disconnect from airline.

2.   Remove Cup Lid and empty coating 

material into a suitable container. 

Clean the gun and cup, preferably in 

a gun wash machine. Clean the cup. 

3.   Check the breather hole in the Lid 

and the Drip Check Lid is not blocked.

4.   Remove air cap (1) and clean. If any 

of the holes in the cap are blocked 

with coating material use a toothpick 

to clean. Never use metal wire which 

could damage the cap and produce 

distorted spray patterns

5.   Ensure the tip of the nozzle (2) is  

clean and free from damage. Build 

up of dried paint can distort the 

spray pattern.

6.   Lubrication – stud/screw (6), packing 

(4) and air valve (11) should be oiled 

each day.

REPLACEMENT OF PARTS

Nozzle (2) and Needle (9) – Remove parts 

in the following order: 7, 8, 9, 1 and 2. 

Replace any worn or damaged parts and 

re-assemble in reverse order. 

Recommended tightening torque for 

nozzle (2) 9.5-12 Nm (80-100 lbf in). 

Packing – Remove parts  7, 8, 9. Unscrew 

cartridge (4). Fit new cartridge finger 

tight. Re-assemble parts 9, 8, and 7 and 

tighten cartridge (4) with spanner suffi-

cient to seal but to allow free movement 

of needle. Lubricate with gun oil.

Air Valve Seal Kit (16) – (Refer to photos 

1 to 28 and fig 2) 

Spreader valve (5) – Caution: always 

ensure that the valve is in the fully open 

position by turning screw fully counter-

clockwise before fitting to body.

SPECIFICATION

Air supply connection: 

Universal 1/4" BSP and NPS

Maximum static Air inlet pressure: 

P

1

 = 12 bar (175 psi)

Nominal gun Air inlet pressure  

with gun triggered: 

2 bar (29 psi) 510, 513 & 522  

Trans-Tech Air Cap

Maximum Service temperature: 40°C

Gun Weight: 412 g

MATERIALS OF CONSTRUCTION

Gun body: Anodized Aluminum

Nozzle: Stainless Steel

Needle: Stainless Steel

Fluid Inlet / Fluid Passages: 

Anodized Aluminum 

Trigger: Nickel Plated Steel

Air Cap Specifications

SP-100-510-K 

10.0 CFM @ 29 psi inlet 

Fan Pattern Max: 10.6"

SP-100-513-K 

14.1 CFM @ 29 psi inlet 

Fan Pattern Max: 13.8"

SP-100-522-K 

14.5 CFM @ 29 psi inlet 

Fan Pattern Max: 13.8"

Summary of Contents for TRANS-TECH GRAVITY FEED

Page 1: ...EN SB 2 540 J 9 2015 1 10 SERVICE MANUAL OPERATION MANUAL TRANS TECH GRAVITY FEED SPRAYGUN...

Page 2: ...lied is NOT suitable for use with Halogenated Hydrocarbons Static Electricity can be generated by fluid and or air passing through hoses by the spraying process and by cleaning non conductive parts wi...

Page 3: ...Spindle 1 12 Trigger Stud and Screw SP 617 CR K 1 13 Connector SP 611 K 1 14 Plug JGA 132 1 17 Retaining Ring and Seals SPK 102 K 1 18 Clip Seal and Pin Kit GTI 428 K5 1 21 Cup Gasket Pack of 5 KGP 13...

Page 4: ...pressure when gun is not in use PREVENTATIVE MAINTENANCE 1 Turn off air and relieve pressure in the supply lines or if using QD system disconnect from airline 2 Remove Cup Lid and empty coating mater...

Page 5: ...Using Service Tool SPN 7 engage groove behind the Valve Seat 6 Remove Valve Seat 7 Push out the Front Airvalve Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front S...

Page 6: ...strument 14 Fit new Seal to Service Tool 15 Fit Seal to Housing 10 16 Replace Valve 11 17 Replace Valve Spring and screw in Housing 10 18 Tighten Housing 19 Fit Needle 9 20 Fit Spring 8 and Knob 7 21...

Page 7: ...gun motion too fast Too much or too fast drying thinner Too much atomization air pressure Air pressure too high Gun tip too far from work surface Gun motion too fast Gun out of adjustment Packing nut...

Page 8: ...are Packing nut too tight Dry packing Fluid tip or needle worn or damaged Foreign matter in tip Fluid needle spring broken Wrong size needle or tip Cup loose on gun Cup gasket worn or missing below cu...

Page 9: ...connects MPV 60 K3 Air Inlet Swivel Pack of 3 Installs into gun to enable user to control and reduce air usage at the gun Replaces SP 637 plug SP 402 K Air Adjusting Valve Paint Spray Respirators 40 1...

Page 10: ...te an authorized distributor contact one of our international sales and customer support locations below USA Canada www devilbiss com info carlisleft com Tel 1 800 992 4657 Fax 1 888 246 5732 United K...

Page 11: ...ES SB 2 540 J 9 2015 ES 1 10 MANUAL DE SERVICIO MANUAL DE OPERACI N COMPACT PISTOLA PULVERIZADORA POR GRAVEDAD TRANS TECH...

Page 12: ...s zonas de trabajo Este equipo tal y como se suministra NO es adecuado para su uso con Hidrocarburos Halogenados La Electricidad Est tica puede ser generada por el paso de fluido y o aire por los mang...

Page 13: ...K 1 14 Tap n JGA 132 1 17 Ret n y juntas SPK 102 K 1 18 Kit de clip junta y perno paq de 5 GTI 428 K5 1 21 El guarnici n de la copa paq de 5 KGP 13 K5 1 22 El montaje conjunto de copa 1 23 Herramienta...

Page 14: ...ierre siempre el suministro de aire y alivie la presi n cuando la pistola no se est utilizando MANTENIMIENTO PREVENTIVO 1 Cierre el suministro de aire y alivie la presi n en los manguitos de sumin ist...

Page 15: ...iento de la v lvula 6 Retire el asiento de la v lvula 7 Haga salir la junta delantera de la v lvula de aire empu jando con el dedo 8 Ponga la pistola boca abajo y deje que se caiga la junta 9 Instale...

Page 16: ...amienta de manten imiento 15 Coloque la junta en el aloja miento 10 16 Vuelva a colocar el husillo 11 17 Vuelva a colocar el muelle de la v lvula y el tornillo en el alojamiento 10 18 Apriete el aloja...

Page 17: ...muy r pido Pistola desajustada Tuerca de la empaquetadura floja Empaquetadura gastada o seca Tuerca de la empaquetadura muy apretada Empaquetadura seca Punta de fluido o aguja gastada o da ada Materi...

Page 18: ...abricante de la pintura Limpie y prepare debidamente Cubeta floja en la pistola Guarnici n de la cubeta gastada o falta debajo de la cubeta Roscas de la cubeta sucias Demasiado flujo de material Mater...

Page 19: ...ositivos de desconexi n r pida de alto flujo DeVilbiss MPV 60 K3 Articulaci n giratoria de entrada de aire paquete de 3 Inst lela en la pistola para permitir al usuario controlar y reducir el uso de a...

Page 20: ...Para asistencia t cnica o para localizar un distribuidor autorizado p ngase en contacto con uno de nuestros centros internacionales de ventas y apoyo al cliente listados a continuaci n EE UU Canad www...

Reviews: