background image

 6 

 

 

CAUTION: 

The air cap can be immersed in solvent for cleaning.  If orifices are clogged, use a broom   

straw or toothpick to remove obstruction.  Never use a steel wire or hard instrument.  This will 
damage  
air cap and result in a distorted spray pattern. 
 

NOTE: 

Do not immerse any plastic parts in solvent for long time. 

 

CAUTION: 

Lubrication 

Do not lubricate to any portions where not instructed 
Lubricate one drop of Gun Lube SSL-10 daily to the following portions. 
Lubricate regularly, Trigger Bearing Stud (22), Air Valve Stem (15) where it enters the valve body and 
the  
Needle (9) where it enters the Packing Nut (19). 
When installing Air Cap (2), make sure no foreign materials adhered on Retaining Ring (1) and thread 
of  
Baffle (6) and then oil one drop of Gun Lube SSL-10. 
Apply non-silicone grease lightly on Needle Spring (10) and Air Valve Spring (16). 
Do not apply to much grease as it may clog the air passage. 
 
Lubricate daily to the following portions.    For lubrication, SSL-10 Gun Lube is recommended. 
 
 
A)  Trigger Bearing Stud 
 
B) Needle 

Packing 

 
 
C)  Thread of Pattern Valve 

Thread of Adjusting Screw 

 
D) Retaining 

Ring 

 
E)  Air Valve Stem 
 
 
 

REPLACEMENT OF PARTS 

 

CAUTION: 

Be careful not to touch the point of Needle (9) as it is sharp. 

When removing Fluid Tip (4), Adjust Screw (11) and Needle Spring (10) should also be removed and   
Needle (9) should be withdrew or retreated.    Turn the Pattern Valve (14) fully counter-clockwise   
Tools should be 1/2” offset wrench, box wrench or DeVilbiss wrench WR-103, do NOT use open wrench 
or adjustable wrench. 
Recommended torque of fluid tip is 24~27N.m. 
To replace Fluid Inlet Nipple and Air Inlet Nipple (25), apply LOCKTIGHT 242 and tighten.   
Recommended torque 20N

m. 

 

 

Summary of Contents for MSV-512

Page 1: ...ovided in the spraying and mixing areas Users must comply with all local and national codes of practice and insurance company requirements governing ventilation fire precautions operation maintenance and housekeeping of work stations HALOGENATED HYDROCARBON SOLVENTS for example 1 1 1 Trichloroethane and Methylene Chloride can chemically react with aluminum and galvanised or zinc coated parts and c...

Page 2: ...vice The materials used in the construction of this equipment are bearing in mind the warning on Halogenated Hydrocarbon solvent resistant enabling the equipment to be cleaned using gun cleaning machines However this equipment must not be left inside the gun cleaning machine for prolonged period of time after the automatic cleaning cycle has been completed The solvents used in the gun cleaning mac...

Page 3: ...Weight 470g Air Inlet Thread G1 4 Fluid Inlet Thread G3 8 standard G1 4 optional Fluid Supply Pressure Feed Air Consumption 278L min Air Cap Pressure 0 20Mpa 805 807 Air Cap Pressure Air Consumption L min 278 150 200 250 300 350 400 0 07MPa 0 11MPa 0 16MPa 0 20MPa 0 24MPa 0 28MPa L min Gun Inlet Pressure 0 10MPa 0 15MPa 0 20MPa 0 25MPa 0 30MPa 0 35MPa Recommended Applicable Range Air Cap Pressure ...

Page 4: ...04270 MSG 16 Adjusting Screw 1 12 805277 SST 8453 K5 Circlip Kit of 5 1 13 SSG 8190 K5 O Ring Kit of 5 1 14 804274 MSG 498 Pattern Valve Assy 1 15 803929 JGS 431 Air Valve Stem 1 16 803936 JGV 262 K5 Spring Kit of 5 1 17 803910 JGK 449 Air Valve Assy 1 18 803855 JGV 463 Needle Packing 2 pcs 1 19 806286 34411 122 K3 Needle Packing Nut Kit of 3 1 20 803916 JGS 108 1 Trigger 1 21 805281 JGX 46 K10 Ci...

Page 5: ...rder to get uniform finishing the spray gun should be hold vertically toward the painting surface To adjust the fluid delivery keep the needle full open not tightening the Adjusting Screw so that the delivery can be adjusted at the material supply line It leaves the abrasion of the Fluid Tip 4 and the Needle 9 the minimum The paint should be filtered through 60 90 mesh filter before use MAINTENANC...

Page 6: ...one drop of Gun Lube SSL 10 Apply non silicone grease lightly on Needle Spring 10 and Air Valve Spring 16 Do not apply to much grease as it may clog the air passage Lubricate daily to the following portions For lubrication SSL 10 Gun Lube is recommended A Trigger Bearing Stud B Needle Packing C Thread of Pattern Valve Thread of Adjusting Screw D Retaining Ring E Air Valve Stem REPLACEMENT OF PARTS...

Page 7: ...hin material Jerky or fluttering spray Insufficient material in the tank or an obstruction in the line Gun material passage plugged Worn needle packing 18 Loose or damaged fluid tip Fill tank or clean obstruction Clean Replace Tighten or replace Fluid leaking from needle packing nut 19 Loose needle packing nut 19 Worn or stuck needle packing 18 Tighten Replace or lubricate Dripping from fluid tip ...

Page 8: ...DESCRIPTION KB 555 800223 Pressure Cup 2 Quart AD 404 J 800029 Adapter 1 4 NPS M 3 8 NPS F WR 103 800314 Wrench SSL 10 805153 Gun Lube 42884 214 K5 806472 Cleaning Brush Kit of 5 KK 5033 805 Air Cap Test Kit KK 5033 807 Air Cap Test Kit ...