Smoke Alarm - SMSZB-120 – Technical manual
Develco Products A/S
Olof Palmes Allé 40
http://develcoproducts.com
DK-8200 Aarhus N
9
4.1.2.2
Commands
The identify cluster has 2 commands as server.
Id#
Name
Payload
Man/Opt
Relevance and ref.
0x00
Identify
Uint16 - Identify Time (seconds)
M
0x01 Identify
Query none
M
The identify cluster has 1 command as client.
Id#
Name
Payload
Man/Opt
Relevance and ref.
0x00
Identify Query
Response
Uint16 - Identify Time (seconds)
M
4.2
IAS Zone Device – EP 0x23
4.2.1
IAS Zone - Cluster id 0x0500
The IAS Zone cluster is described in ZigBee Cluster Library Specification
4.2.1.1
Attribute
Id#
Name
Type
Man/Opt
Relevance and ref.
0x0000 Zone
State
8-bit
Enumeration
M
0x0001 Zone
Type
16-bit
Enumeration
M
Hard coded to 0x0028
FireSensor
0x0002
Zone Status
Uint16
M
The following bits are
supported:
Bit0: Alarm 1
Bit3: Battery (30 days left)
Bit4: Supervision reports
Bit5: Restore reports
Bit8: Test
0x0010
IAS CIE Address
Valid 64-bit IEEE address
M
0x0011
ZoneID Uint8
M
4.2.1.1.1
Zone State
The device will automatically start to scan the network for an IAS Zone client in a predefine interval. When the
client is found it will automatically attempt to enrol. When it has successfully enrolled the Zone Status command
is send every 5 minutes.