On completion of the process DB90-TX settings will have the following values:
Audio Default Settings
•
Input: analog
• A/D amplifier gain: 0 dB
•
Channels: 2
•
E Sample rate: MPEG 1/48 kHz
•
Quality: 6 Excellent
•
Stereo mode: Stereo
•
CRC: ON
•
Emphasis: None
Network Default Settings
All the Network Settings will remain unchanged.
Stream Server Default Settings
•
Name: DB9000-TX
•
Port: 5000
•
Pre-buffer: 96k
•
Max connections: 2
WEB Server Default Settings
•
Port: 80
•
Username: user
•
Password: pass
RS-232 Default Settings
•
Baudrate: 9600
•
Port : 9000
•
Password: pass
ATTENTION:
Please note that the WEB Server’s Port, Username and Password will be
changed, so it is possible the page not to be loaded after restoring factory defaults. You may be
asked to re-enter the encoder’s address and/or username and password.