![DEVA Broadcast DB7001 Maintenance And Operation Instruction Manual Download Page 74](http://html.mh-extra.com/html/deva-broadcast/db7001/db7001_maintenance-and-operation-instruction-manual_2488558074.webp)
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 74 -
Enter the desired alarm recipients in
E-mail 1
and/or
E-mail 2
fields. Fill in your e-mail account
settings:
Sender
,
Username
and
Password
,
Server
,
SNMP port
and
Connection
type.
We recommend you to use the [Test] button and generate a test e-mail, which upon success will
be delivered to the specified E-mail 1 and/or E-mail 2.
Example of Test E-mail Message:
DB7001 Test Message.
Please do not reply to this e-mail.
UECP UDP Relay & UECP TCP Server
The unit can relay the received RDS as a UECP stream. There are two possible options:
Option 1
– via UDP, where the device sends the received RDS as UECP encoded UDP packets
unconditionally to the specified IP Address and Port. The receiver could be an RDS/RBDS Encoder
SmartGen, other RDS Encoder, or Monitoring Software.
Option 2
– via TCP. The unit has built in server and a Monitoring Software to receive the UECP
encoded RDS data could be connected to the unit.
USB Port
[Enabled]/[Disabled] USB port.