![DEVA Broadcast DB7001 Maintenance And Operation Instruction Manual Download Page 67](http://html.mh-extra.com/html/deva-broadcast/db7001/db7001_maintenance-and-operation-instruction-manual_2488558067.webp)
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 67 -
Alarm Active Action
– In this section are defined the actions to be undertaken in case of an
RF, Audio, MPX, Pilot or PI Protection alarm is generated. The following options for reaction are
available - Audio Mute, MPX Mute, Switch to Backup Station. The applied settings are applicable
for both – the main and backup stations, the option “Switch to backup station” excluded as it is
applicable only for the main station.
NOTE:
For further information on how to set the Alarms
refer to “Alarms Settings Screen” on
Average & Peak Adjustments
section is used for setting of the indicators response times. Attack
and Release times set the rate in which the indicators’ level will change in response to the signal.
For most of the applications (including this one), the recommended attack time is shorter than the
release time.
Peak-hold time – Permits retaining and displaying the peak value reached by the signal for a
period of time predefined by the user.