GRAPHS PAGE
Enter the Main Menu page and select the Graphs icon, press [OK] button to enter the menu.
Graph page represents the value of a measured signal over time. The X axis of the data plot area
represents the elapsed time in seconds. New peak value sample is added to the data graph every
125ms. Up to 20 seconds of measurement history is available for each signal. The newest sample
is on the right side of the graph. The current signal name and measurement unit are displayed in
the top left corner of the data plot.
A bar graph indicator, placed on the right part of the screen, is used to display the instantaneous
value of the selected signal. The low, average and high values of the measured signal are represented
in shaded color. The following signals can be selected:
•
RF level
– from
-10dBμV
to
110dBμV
;
•
Multipath
level from
0%
to
100%