Customer Documentation DEV 2161, DEV 2162, DEV 2165
Copyright DEV Systemtechnik GmbH 2011-2017
9
5
OPERATION OF THE PRODUCT
After going through the installation steps as described above, the device is
ready to use.
5.1
OPERATION VIA THE DEVICE PANEL
Beside the bias (or LNB power) push button(s) (please refer to chapter
3.1.1), there is (are) no element(s) to be operated. The operating status of
each splitter unit and of each LNB power (or bias) supply is indicated via
LEDs, which were already described in chapter 3.1.1 as well.
6
CONNECTORS
AC Power Plug (at the external power supply)
Connector:
IEC rubber connector (male) IEC 60320 C14
Connector screws:
none
AC Power Plug
Pin
Functionality
Pin 1
L (Live/Phase)
Pin 2
PE (Protective Earth)
Pin 3
N (Neutral)
DC Connector Plug (at the chassis)
Connector:
DC coaxial connector plug for connector with
OD (Outer Diameter): 5.5 mm (0.22") &
ID (Inner Diameter):
2.1 mm (0.08")
Connector screws:
none
DC Connector Plug
Pin
Functionality
Pin 1 (inner)
positive DC-Voltage
(+18 V nominal)
Pin 2 (outer)
GND
7
TECHNICAL DATA AND OPTIONS
The technical data and the options are stated in the data sheet; please refer
to
www.dev-systemtechnik.com
.
8
SPARE PARTS
External power supply; 18 V DC, 60 W
DEV 79-0163
1
2
3
1
2