LOCON 24, 48 and 64 options
Deutschmann Automation GmbH & Co. KG
32
Instruction manual LOCON 24, 48, 64 , LTC, TERM 24 and TERM 6 V. 8.8
24.7.12
Example:
set direction for direction cams
Cam
100
200
Driving direction
Position
OUT
Comment
100
HIGH
Edge is detected, direction is eva-
luated, output switched
200
LOW
Edge is detected, direction is eva-
luated, output is switched off
199
LOW
Edge is detected, direction is eva-
luated, output is not updated
99
LOW
Edge is detected, direction is eva-
luated, output is not updated
100
HIGH
Edge is detected, direction is eva-
luated, output is set
In the first cycle after switching on the device and after each program change, all outputs are
updated (independent of the programmed direction), that means, in this cycle the LOCON acts
like a cam control without direction cams.
Afterwards an update of the outputs only takes place if the encoder’s direction of rotation corre-
sponds to the programmed direction of the output and a cam edge (switch on- or switch off-point)
is present.
In the first cycle after switching on the device, it acts like a cam control
without direction cams!
7.8
Angle-time cam
LOCON 24, 48 and 64 are available optionally with angle-time cams. The switch-on point is
dependent on the angle, the switch-off point is defined by a time period (1 through 32500 ms).
Please note that an idle time compensation is not possible for this optional adjustment.
Please refer to chapter "Entering angle-time-cam" on page 70 for a detailed description.
Note:
The switch-on point and the duration must not have the same value.
-> otherwise: Error 22.
7.9
Memory expansion
LOCON 24, 48 and 64 feature a memory for 1,000 data records as standard. Optionally, the
memory can be upgraded for 1,500 data records.
7.10 Offline programming
It is possible to program the LOCON offline on a PC without the unit itself having to be connected
to the PC when programming.