![DEUTSCHMANN AUTOMATION SPEEDY Series Instruction Manual Download Page 19](http://html1.mh-extra.com/html/deutschmann-automation/speedy-series/speedy-series_instruction-manual_2488412019.webp)
30.1.20
Instruction manual dynamic switching accelerator SPEEDY V. 3.1
19
Deutschmann Automation GmbH & Co. KG
Technical data
7
Technical data
7.1
SPEEDY-100V-1A
SPEEDY-100V-4A
Operating voltage
10... 30V, max 1 W (unloaded)
10... 30V, max 1 W (unloaded)
Current consumption
Max. 40mA (idle state)
max. 3A (at switching instant)
Max. 40mA (idle state)
max. 3A (at switching instant)
Inputs
4
R
i
> 3.9 k
U
L
= OV - 3V, U
H
= 12V - 30V
4
R
i
> 3.9 k
U
L
= OV - 3V, U
H
= 12V - 3V
Outputs
2
I
out
< 1A steady load
U
out-Stat
> operating voltage - 1V
U
out-pulse
= 88V .. 100V
2
I
out
4A steady load / temporarily 5A (max. 1min.)
U
out-Stat
> operating voltage - 1V
U
out-pulse
= 88V .. 100V
Programs
Can be set via 5 rotary switches
other customized programs on request
Can be set via 5 rotary switches
other customized programs on request
Pulse length
Can be set 1 - 10ms
Can be set 1 - 10ms
Switching delay
< 300
μ
s (without input interference
suppression)
< 300
μ
s (without input interference suppression)
Recovery time
Max. 150ms at 1A load and 10ms pulse Max. 200ms at 3A load and 10ms pulse
Housing
Plastic for EN mounting rail mounting
(can be lined up)
W x H x D: 25 x 79 x 90.5mm
Plastic for EN mounting rail mounting (can be
lined up)
W x H x D: 25 x 79 x 90.5mm
Conductor connection
Via plug terminal block up to 2.5mm
2
Via plug terminal block up to 2.5mm
2
Display
Optional LED status display of the
inputs, outputs and supply voltages
Optional LED status display of the inputs, outputs
and supply voltages
SPEEDY-100V
7.2
SPEEDY-50V
SPEEDY-50V-1A
SPEEDY-50V-4A
Operating voltage
10... 30V, max 1 W (unloaded)
10... 30V, max 1 W (unloaded)
Current consumption
Max. 40mA (idle state)
max. 3A (at switching instant)
Max. 40mA (idle state)
max. 3A (at switching instant)
Inputs
4
R
i
> 3.9 k
U
L
= OV - 3V, U
H
= 12V - 30V
4
R
i
> 3.9 k
U
L
= OV - 3V, U
H
= 12V - 3V
Outputs
2
I
out
< 1A steady load
U
out-Stat
> operating voltage - 1V
U
out-pulse
= 44V .. 50V
2
I
out
4A steady load / temporarily 5A (max. 1min.)
U
out-Stat
> operating voltage - 1V
U
out-pulse
= 44V .. 50V
Programs
Can be set via 5 rotary switches
other customized programs on request
Can be set via 5 rotary switches
other customized programs on request
Pulse length
Can be set 1 - 10ms
Can be set 1 - 10ms
Switching delay
< 300
μ
s (without input interference
suppression)
< 300
μ
s (without input interference suppression)
Recovery time
Max. 150ms at 1A load and 10ms pulse Max. 200ms at 3A load and 10ms pulse
Housing
Plastic for EN mounting rail mounting
(can be lined up)
W x H x D: 25 x 79 x 90.5mm
Plastic for EN mounting rail mounting (can be
lined up)
W x H x D: 25 x 79 x 90.5mm
Conductor connection
Via plug terminal block up to 2.5mm
2
Via plug terminal block up to 2.5mm
2
Display
Optional LED status display of the
inputs, outputs and supply voltages
Optional LED status display of the inputs, outputs
and supply voltages
Summary of Contents for SPEEDY Series
Page 2: ...Handbuch Art Nr V3140E...
Page 22: ......