30.1.20
Instruction manual dynamic switching accelerator SPEEDY V. 3.1
13
Deutschmann Automation GmbH & Co. KG
SPEEDY switching modes
5.2
Switching mode 1
In switching mode 1, input 1 is switched to output 1 and input 2 is switched to output 2. The dura-
tion of the overexcitation pulse is set at the inputs 3 and 4.
Picture 2:
Switching mode 1
Input 3
Input 4
Pulse
0 VDC
0 VDC
1 ms
+24 VDC
0 VDC
2 ms
0 VDC
+24 VDC
5 ms
+24 VDC
+24 VDC
10 ms