Deutronic D-IPS Manual - EN
- 15 / 19 -
03 / 2015
D-IPS® und DEUTRONIC® sind eingetragene Marken der Deutronic Elektronik GmbH. Technische Änderungen und Irrtümer vorbehalten.
D-IPS® and DEUTRONIC® are registered trademarks of the Deutronic Elektronik GmbH. Technical modificationses and mistakes reserved.
®
®
Command list of D-IPS - C series
250W, 350W, 500W:
Running system commands:
DEV:GO
Description:
Power module will be activated
Return value:
<ACK>
DEV:STOP
Description:
Power module will be switched off
Return value:
<ACK>
Output control:
OUT:UOUT?
Description:
Measurement of current voltage at the output
Return value:
<Z>
OUT:UOUTS?
Description:
Measurement of nominal voltage for output
Return value:
<Z>
OUT:IOUT?
Description:
Measurement of actual current at the output
Return value:
<Z>
OUT:IOUTS?
Description:
Measurement of nominal current for output
Return value:
<Z>
OUT:UOUTS,x
Description:
Setting of nominal value for output voltage
Parameter:
x
= 0.0 to max. value e.g. 24.0 [V] (system-specific)
Return value:
<ACK> / <NAK>
Basic setting:
0.0
OUT:IOUTS,x
Description:
Setting of nominal value for output current
Parameter:
x
= 0.0 to max. value e.g. 20.0 [A] (system-specific)
Return value:
<ACK> / <NAK>
Basic setting:
0.0