Important Note: 

Only qualified personnel is allowed to use the device for specified 
application. 
Read the instruction manual carefully and pay attention to the safety 
instructions and manufacturer´s requirements in any case! 
 

Deutronicstrasse 5 
84166 Adlkofen / Germany 

Tel.: +49 (0)8707 / 920-199 
Fax: +49 (0)8707 / 1004 

E-Mail: 

[email protected]

 

http://www.deutronic.com 

 

Summary of Contents for D-IPS 250C

Page 1: ...takes reserved D IPS Manual for the power supply 1AC D IPS 250C 500C 3AC D IPS 350 3C D IPS 500 3C Controllable Version Important Note Only qualified personnel is allowed to use the device for specified application Read the instruction manual carefully and pay attention to the safety instructions and manufacturer s requirements in any case Deutronicstrasse 5 84166 Adlkofen Germany Tel 49 0 8707 92...

Page 2: ...ernet 12 9 a The RS232 interface 12 9 b The Ethernet Interface order option 12 10 Command structure description of communication 13 11 Notes 18 12 Annex accessories 19 13 Service Center Repair 19 Device features Innovative power supply for professional OEM application Mounting on TS35 rail screw fastener via adapter accessory available High efficiency Standby power 1 5 W LC Display to display the ...

Page 3: ... work on applied voltage To avoid overheating of the power supply through insufficient convection a miminum distance to the other modules must be maintained 10cm in vertical direction and 2cm in horizontal direction IMPORTANT SAFETY INSTRUCTIONS 1 Store these instructions The manual contains important safety and operating instructions 2 Only suspend the Power supply to the temperature ranges speci...

Page 4: ...Installation DIN rail mounting Mounting Hang up the device with the DIN rail guide into the top edge of the DIN rail and press down to snap in 1 DC output 8 User menu LC display 2 Communication Interface 9 Signal LED 3 C1 Interface 10 DC OK LED 4 C2 Interface 11 mains connection depending on the device version 1AC 3AC 5 UP button select parameters 6 DOWN button select parameters 7 ENTER button edi...

Page 5: ...he device must be switchable in volt free mode outside the power supply eg by a breaker or the primary side cable protection The ground conducter has to be connected Recommended minimum cross section of 1 5mm or AWG16 for North America The mains cords must be dimensioned and secured sufficient The output lines must be dimensioned or secured separately according to the device s output current A suf...

Page 6: ...tion The controllable power supplies of the D IPS C series have following configuration possibilities Configuration at the device directly via buttons control Configuration of the device via communication protocol RS 232 Ethernet etc Optional Special customer settings preconfigured possible ex works User interface display At the top of the startdialogue the values for voltage and current as well a...

Page 7: ...ows the actual values of voltage and current and in set mode each level or function 6 Configuration of the source for output voltage and current The output voltage and the output current can be adjusted by the following sources Internal input Buttons on the unit Analog input 0 10V 4 20mA Digital input RS232 option Ethernet etc 6 a Source input for the voltage by buttons Press ENTER Select with the...

Page 8: ...ection must be done once again Exit from this menu level with any button Src V Press the buttons and at the same time to get out of the menu level without overtaking the source Press the buttons and simultaneous once again to get out of the menu then it shows the current values for current and voltage 6 b Source input for the current by buttons Press ENTER Select with the buttons or Src A in this ...

Page 9: ...xample shows the configuration of the reference values for the output voltage Reference values for the output current will be adjusted in the same way Press button ENTER for the first menu level The display shows the start symbol of the menu Choose with the buttons or the voltage target value Int V in this menu item Press ENTER for the input of the voltage target value The changeable digit is mark...

Page 10: ...nimum activation voltage control of power consumption Inhibit start release at phase loss 3AC only Min max start release temperature Min max operating temperature 7 b OUTPUT Programmable output variables OEM Current limit overload behavior Output characteristics I const P const Hiccup Fuse Mode Overload behaviour Power reserve by time Operation control programmable time raster control Data recordi...

Page 11: ... and level 1 DIGITAL OUT 1 High max 20mA 2 DIGITAL OUT 2 High max 20mA 3 GND 4 NC 5 DIGITAL OUT 3 OC max 50mA 6 DIGITAL OUT 3 GND 7 DIGITAL OUT 4 OC max 50mA 8 DIGITAL OUT 4 GND 9 5VDC 100mA Auxiliary voltage floating for active sensors 10 GND AUX Connector C2 Control Sensing PIN Configuration Function and level 1 Relay1 1 2 Make contact 2 Relay1 3 ANALOG IN 1 Spannung Voltage 4 ANALOG IN 1 Spannu...

Page 12: ... DSR not used 7 RTS not used 8 CTS not used 9 RI Not used RS 232 Interface parameters Baudrate 57600 baud Datenbits 8 Parity none Stopbit 1 Handshake none Protokoll STX ETX further details are described below 9 b The Ethernet Interface order option The Ethernet Interface is used to connect the controllable power supply of D IPS C series to a 10 100Mbit Ethernet TCP IP or UDP Network connection RJ4...

Page 13: ...characters are used for the control of data transmission Control characters Value Start character STX 0x02 End character ETX 0x03 Command mode Extension Example Read Command R OUT UOUTS request voltage reference value Write Command W parameter OUT UOUTS 10 0 set voltage reference value to 10 0V Example STX OUT UOUTS ETX Used shortcuts STX Start of Text ASCII Code 2 will sent before start of a comm...

Page 14: ...and one or two sub group command these are connected with Then the marking of the type of the command follows The possible commands are divided into three types READ WRITE EXECUTE The differentiation is made by the appropriate sign after the main command READ WRITE EXECUTE no sign At the WRITE commands for the input of voltage current and power a number input with one decimal place must be done af...

Page 15: ...ff Return value ACK Output control OUT UOUT Description Measurement of current voltage at the output Return value Z OUT UOUTS Description Measurement of nominal voltage for output Return value Z OUT IOUT Description Measurement of actual current at the output Return value Z OUT IOUTS Description Measurement of nominal current for output Return value Z OUT UOUTS x Description Setting of nominal val...

Page 16: ... by buttons on the display Return value ACK SORV DIG Description Switching to the digital input of nominal value for voltage RS232 interface Return value ACK SORV ANL Description Switching to the analog input of nominal value for voltage analog input 0 10V Return value ACK Current source SORA INT Description Switching to the internal input of nominal value for current entered value by buttons on t...

Page 17: ...R DIN2 Description State of digital input 2 Return value SET CLEAR PER DIG1 ON Description State of digital output 1 Subcommand ON OFF Return value ACK Basic setting OFF PER DIG2 ON Description State of digital output 2 Subcommand ON OFF Return value ACK Basic setting OFF PER DIG3 ON Description State of digital output 3 Subcommand ON OFF Return value ACK Basic setting OFF PER DIG4 ON Description ...

Page 18: ...d DEUTRONIC sind eingetragene Marken der Deutronic Elektronik GmbH Technische Änderungen und Irrtümer vorbehalten D IPS and DEUTRONIC are registered trademarks of the Deutronic Elektronik GmbH Technical modificationses and mistakes reserved 11 Notes ...

Page 19: ...led fault description is included The needed return service scripture as well as the world wide service partner addresses you will find on our webpage www deutronic com in the menu item service worldwide Disclaimer The customer is responsible for the use of the device according to the specifications Regardless of the type Deutronic is not liable for damage incurred through the use of the device Co...