TABLE 1
Sidewall venting selection chart
Heating unit
MODEL
Connecting
pipe ( " )
Input
(USGPH)
Sidewall venter
Reducer
( " )
Package
number
Burner
AM(i)-076 to 110
6
0.65 to 0.92
SWV-1M-2S
SMH-1-DE
Beckett or Riello
AM(i)-120 to 140
6
1.00 to1.20
SWV-2M-2S
SMH-4-DE
Beckett or Riello
AME-15 to 25
6
0.65 to 0.85
SWV-1M-2S
SMH-1-DE
Beckett or Riello
AM(i)T-075 to 105
5
0.50 to 0.75
SWV-1M-2S
6 - 5
SMH-3-DE
Beckett or Riello
AM(i)T-120 to 155
6
0.85 to 1.10
SWV-2M-2S
SMH-4-DE
Beckett or Riello
HM(R)-080 to 121
5
0.75 to 1.00
SWV-1M-2S
6 - 5
SMH-3-DE
Beckett or Riello
HM(i)-103 to 159
6
0.85 to 1.35
SWV-2M-2S
SMH-4-DE
Beckett or Riello
HM-185 to 212
8
1.50 to 1.75
SWV-2M-2S
6 - 8
SMH-5-DE
Beckett or Riello
HMD-124 to 208
7
1.00 to 1.50
SWV-2M-2S
6 - 7
SMH-6-DE
Beckett or Riello
HME-15 to 20
6
0.65 to 0.75
SWV-1M-2S
SMH-1-DE
Beckett or Riello
HME-23 to 25
6
0.85 to 1.10
SWV-2M-2S
SMH-4-DE
Beckett or Riello
HML-115 to 175
6
1.00 to 1.50
SWV-2M-2S
SMH-4-DE
Beckett or Riello
HMT-012 to 018
6
1.00 to 1.50
SWV-2M-2S
SMH-4-DE
Beckett or Riello
HMS-027 to 035
6
0.65 to 0.85
SWV-1M-2S
SMH-1-DE
Beckett or Riello
HMS-041 to 062
6
1.00 to 1.50
SWV-2M-2S
SMH-4-DE
Beckett or Riello
AMP-075 to 105
5
0.50 to 0.75
SWV-1M-2S
6
– 5
SMH-3-DE
Beckett or Riello
AMP-120 to 155
6
0.85 to 1.10
SWV-2M-2S
SMH-4-DE
Beckett or Riello
LO-1MQH-3M*
5
0.65 to 1.00
SWV-1M-2S
6
– 5*
SMH-1-BR
Brock or Riello
FBR-1*
5
0.65 to 1.00
SWV-1M-2S
7
– 5*
SMH-1-BR
Brock
MBP*
5
0.65 to 1.00
SWV-1M-2S
6
– 5*
SMH-1-BR
Brock, Beckett or Riello
MBP-U*
5
0.65 to 0.85
SWV-1M-2S
6
– 5*
SMH-1-BR
Beckett
MBP-F*
5
0.65 to 1.00
SWV-2M-2S
6
– 5*
SMH-4-BR
Brock or Beckett
CCC*
5
0.50 to 0.85
SWV-1M-2S
SMH-1-BR
Brock or Beckett
LO-2M*
5
1.10 & 1.25
SWV-2M-2S
7
– 5*
SMH-4-BR
Brock
MBP-2*
5
1.10 & 1.25
SWV-2M-2S
6
– 5*
SMH-4-BR
Brock
CMO32 / CMO50*
5
0.65 to 0.75
SWV-1M-2S
6
– 5*
SMH-1-BR
Beckett or Riello
CMO32-II / CMO50-II
Not Available
IB30 / IB32-R*
5
0.65 to 0.75
SWV-1M-2S
6
– 5*
SMH-1-BR
Beckett or Riello
30-RB*
5
0.65
SWV-1M-2S
6
– 5*
SMH-1-BR
Beckett or Riello
32E2*
5
0.75
SWV-1M-2S
6
– 5*
SMH-1-BR
Brock
50E2 / IB50-O*
5
0.65 to 0.75
SWV-1M-2S
6
– 5*
SMH-1-BR
Brock or Riello
* Sidewall vent kit does not include the reducer for the appliances using a 5 inch connecting pipe.