background image

Table of content

1

SAFETY

2

1.1 DANGER, WARNING AND CAUTION . . . . . . . . . . . . . . . . . . . .

2

1.2 IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1.3 DANGER OF FREEZING . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

2

INSTALLATION

3

2.1 POSITIONING THE FURNACE . . . . . . . . . . . . . . . . . . . . . . . . .

3

2.2 CLEARANCES TO COMBUSTIBLE MATERIAL . . . . . . . . . . . . .

3

2.2.1

Heating unit

. . . . . . . . . . . . . . . . . . .

3

2.2.2

Supply air ducts

. . . . . . . . . . . . . . . . .

3

2.3 CONFIGURATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

2.3.1

Upflow installation . . . . . . . . . . . . . . . . .

3

2.3.2

Downflow installation . . . . . . . . . . . . . . .

4

2.3.3

Horizontal installation . . . . . . . . . . . . . . .

4

2.3.4

Suspended installation

. . . . . . . . . . . . . .

4

2.4 ELECTRICAL SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

2.4.1

Conversion from two wires to one wire supply for
models 25kW and more

. . . . . . . . . . . . .

4

2.4.2

208V Power Supply . . . . . . . . . . . . . . . .

5

2.5 INSTALLATION OF THE THERMOSTAT . . . . . . . . . . . . . . . . . .

5

2.5.1

Anticipator adjustment (if required) on thermostat
equipped with heat anticipator adjustment 
. . . . .

6

2.5.2

Air ducts

. . . . . . . . . . . . . . . . . . . . .

6

2.6 SUPPLY AIR ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . .

6

2.7 INSTALLATION OF ACCESSORIES . . . . . . . . . . . . . . . . . . . . . .

7

2.7.1

Humidifier and electronic air cleaner

. . . . . . .

7

2.7.2

Use of a heat pump . . . . . . . . . . . . . . . .

7

3

OPERATION

7

3.1 START-UP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

3.2 USE OF MANUAL FURNACE CONTROLS ON ADVANTAGE

FURNACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

3.3 OPERATING SEQUENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

3.3.1

Heating mode . . . . . . . . . . . . . . . . . . .

8

3.3.2

Cooling Mode . . . . . . . . . . . . . . . . . . .

8

3.3.3

Continuous fan speed

. . . . . . . . . . . . . .

8

3.4 AIRFLOW VERIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

3.4.1

Supply Air Temperature Rise Test

. . . . . . . .

8

3.4.2

High limit verification

. . . . . . . . . . . . . . .

8

4

MAINTENANCE

9

4.1 AIR FILTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

4.2 MOTOR LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

5

FURNACE INFORMATION

9

6

TECHNICAL SPECIFICATIONS

10

7

NOTES

22

List of figures

Figure 1:

Upflow Configuration . . . . . . . . . . . . . . .

4

Figure 2:

Downflow Configuration . . . . . . . . . . . . . .

4

Figure 3:

Horizontal Configuration

. . . . . . . . . . . . .

4

Figure 4:

Conversion from two to one supply wires . . . . .

5

Figure 5:

1-stage thermostat, electric heating only . . . . .

5

Figure 6:

2-stage thermostat, electric heating only . . . . .

5

Figure 7:

1-stage thermostat with outdoor control for 2-stage
function, electric heating only 
. . . . . . . . . . .

5

Figure 8:

1-stage

thermostat,

electric

heating

and

air

conditionning . . . . . . . . . . . . . . . . . . .

6

Figure 9:

2-stage

thermostat,

electric

heating

and

air

conditioning . . . . . . . . . . . . . . . . . . . .

6

Figure 10:

Advantage furnace controls . . . . . . . . . . . .

7

Figure 11:

Comfort Dimensions . . . . . . . . . . . . . . .

14

Figure 12:

Advantage Dimensionsi . . . . . . . . . . . . . .

14

Figure 13:

Électrical diagram, Supreme Comfort PSC . . . .

15

Figure 14:

Électrical diagram, Supreme Advantage PSC . . .

16

Figure 15:

Électrical diagram, Supreme Advantage PSC, 3
phases 
. . . . . . . . . . . . . . . . . . . . . .

17

Figure 16:

Parts list, S

UPREME

Comfort PSC

. . . . . . . .

18

Figure 17:

Parts list, S

UPREME

Advantage PSC . . . . . . .

20

List of tables

Table 1:

Supply air adjustment on cooling mode . . . . . .

7

Table 2:

Technical specifications (120V) . . . . . . . . . .

10

Table 3:

Technical specifications(240V)

. . . . . . . . . .

11

Table 4:

Technical specifications(240V 3 phases)

. . . . .

12

Table 5:

Airflow (CFM) - SUPREME with 1/3 HP motor

. .

13

Table 6:

Airflow (CFM) - SUPREME with 1HP motor . . . .

13

Table 7:

Accessories . . . . . . . . . . . . . . . . . . . .

14

Table 8:

Parts list, S

UPREME

Comfort PSC . . . . . . . . .

19

Table 9:

Parts list, S

UPREME

Advantage PSC . . . . . . .

21

1

Summary of Contents for ADVANTAGE SUPXX-A120D12

Page 1: ...0 INSTALLER SERVICE TECHNICIAN Attention Do not tamper with the unit or its controls Call a qualified service technician USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FU...

Page 2: ...ATION 9 5 FURNACE INFORMATION 9 6 TECHNICAL SPECIFICATIONS 10 7 NOTES 22 List of figures Figure 1 Upflow Configuration 4 Figure 2 Downflow Configuration 4 Figure 3 Horizontal Configuration 4 Figure 4...

Page 3: ...d for use by a qualified technician familiar with safety procedures and who is equipped with the proper tools and test instruments Failure to carefully read and follow all instructions in this manual...

Page 4: ...8 VAC power supply to the control panel thermostat hook up as shown on the wiring diagram 2 1 POSITIONING THE FURNACE WARNING FIRE AND EXPLOSION HAZARD The furnace must be installed in a level positio...

Page 5: ...and or property damage 2 4 ELECTRICAL SYSTEM The SUPREME furnace is completely pre wired and all field wiring must be connected to the terminal blocks on the unit It requires 2 service wires of 240 20...

Page 6: ...t be changed to the 208V position 2 5 INSTALLATION OF THE THERMOSTAT A thermostat must be installed to control the temperature of the area to be heated Follow the instructions supplied with the thermo...

Page 7: ...nd return air connectors to avoid the transmission of vibration To make the unit run even quieter the installer should 1 Use two elbows between each outlet and the supply and return air plenum 2 Cover...

Page 8: ...structions provided with the thermostat or the Fossil Fuel kit for the proper wiring of the furnace and the heat pump The simultaneous operation of the electric elements and the heat pump will cause o...

Page 9: ...on of the average airflow To do that the following formula should be used Liter s 0 82 amps volts Diff temperature C CFM 3 1 amps volts Diff temperature F Tables 5 and 6 show estimated airflows for va...

Page 10: ...rmostat higher than room temperature If the unit does not start up cut the power and call a qualified service technician When calling for service or ordering a replacement part specify the model and s...

Page 11: ...5 9 9 11 5 9 9 11 5 9 9 11 5 9 9 11 5 9 9 Heating Elements Consumption 240V 208V Amp 41 4 35 9 62 1 53 8 75 8 65 7 82 8 71 8 96 5 83 6 103 5 89 7 82 8 71 8 96 5 83 6 103 5 89 7 113 6 98 5 124 3 107 7...

Page 12: ...1 5 9 5 1 5 9 5 1 5 9 5 1 Heating Elements Consumption 240V 208V Amp 41 4 35 9 62 1 53 8 75 8 65 7 82 8 71 8 96 5 83 6 103 5 89 7 82 8 71 8 96 5 83 6 103 5 89 7 113 6 98 5 124 3 107 7 Total Consumpti...

Page 13: ...or Consumption 240V 208V Amp Max 2 6 2 3 5 9 5 1 Heating Elements Consumption 240V 208V Amp 57 8 50 1 72 2 62 6 Total Consumption 240V 208V Amp 60 4 52 3 78 1 67 7 Ampacity 240V 208V Amp 76 66 93 81 S...

Page 14: ...est 5CFM Data taken with air filter in place Table 6 Airflow CFM SUPREME with 1HP motor Furnace equipped with a 1HP 120 blower motor Blower External static pressure inche of W C Speed 0 2 0 3 0 4 0 5...

Page 15: ...559mm 22 25mm 1 SUPPLY ALIMENTATION 508mm x 508mm 20 x 20 REVISIONS REV DESCRIPTION A C DATE PAR Figure 12 Advantage Dimensionsi 451mm 17 3 4 451mm 17 3 4 RETURN 483mm x 483mm 19 x 19 RETOUR Identical...

Page 16: ...Figure 13 lectrical diagram Supreme Comfort PSC 15...

Page 17: ...Figure 14 lectrical diagram Supreme Advantage PSC 16...

Page 18: ...Figure 15 lectrical diagram Supreme Advantage PSC 3 phases ELECTRICAL DIAGRAM DIAGRAMME L CTRIQUE ADVANTAGE AVANTAGE PSC 3 PHASES 17...

Page 19: ...20 23 24 25 28 27 B50147 rev F 7 8 9 10 11 12 13 5 6 REV DESCRIPTION A C DATE PAR B Changement Disjoncteur 22314 2015 05 15 F H C Ajoute support de filtre Change item 1 22388 2015 07 01 F H D TIQUETT...

Page 20: ...10 15 18 20 kW 20 B01889 Motor support band and legs 21 L06K004 Motor 1hp 120v PSC Supreme 20 kW 22 L06K005 Motor 1hp 240v PSC Supreme 20 kW 23 L06G007 Motor 1 3hp 120v PSC Supreme 10 15 18 20 kW 24...

Page 21: ...rev F 9 12 13 14 8 6 7 15 16 17 18 19 10 11 REV DESCRIPTION A C DATE PAR B Changement disjoncteur pour CQC 22326 2015 05 19 F H C Ajoute support de filtre Change item 1 22389 2015 07 01 F H D TIQUETT...

Page 22: ...18 20 23 25 kw 24 B04356 04 Blower assembly 1hp 240V PSC Supreme 20 23 25 27 30 kw 25 Z01I036 Blower 112 9R 1hp Supreme 20 23 25 27 30 kw 26 Z01I035 Blower 112 8R 1 3hp Supr me 10 15 18 20 23 25 kw 27...

Page 23: ...7 NOTES 22...

Page 24: ...23...