the warm air temperature exceeds 200°F (93°C).
Remove the obstruction and the elements should restart
after a few minutes.
4
MAINTENANCE
WARNING
E
LECTRICAL
S
HOCK HAZARD
Turn OFF power to the furnace before any
disassembly or servicing.
Failure to do so can result in death, bodily injury
and/or property damage.
Preventive maintenance is the best way to avoid
unnecessary expense and inconvenience.
Have
your heating system inspected by a qualified service
technician once a year.
Do not attempt to repair the
furnace or its controls. Call a qualified service technician.
Before calling for repair service, check the following
points:
1. Check fuses or the circuit breakers;
2. Check if the 15 A circuit breaker on the furnace is
disengaged;
3. Set the thermostat higher than room temperature.
If the unit does not start up, cut the power and call
a qualified service technician.
When calling for service or ordering a replacement part,
specify the model and serial number of your appliance.
4.1
AIR FILTER
The disposable filter should be replaced twice a year.
The presence of animal hair, dust, etc. may necessitate
more frequent changes. Dirty filters have an adverse
effect on the performance of the central heating system.
4.2
MOTOR LUBRICATION
Do not lubricate the blower motor, since it is permanently
lubricated.
5
FURNACE INFORMATION
Model: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial number: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Furnace installation date: . . . . . . . . . . . . . . . . . . .
Service telephone # - Day: . . . . . . . . . . . . . . . . .
Night: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dealer name and address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START-UP RESULTS
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ElementsTotal current : . . . . . . . . . . . . . . . . . . . . .
Supply air temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Return air temperature: . . . . . . . . . . . . . . . . . . . .
Supply air duct static pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Return air duct static pressure: . . . . . . . . . . . . .
Total pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calculated air flow: . . . . . . . . . . . . . . . . . . . . . . . . .
Current consumed by the blower motor: . . . . . . . . . . . . . . . . . . . . . . . .
Current consumed by the accessories: . . . . .