GAVIN-6C Instruction Manual
- 29 -
key to set the value of the item.
AIL
▶
AIL
: This parameter is used to set the mixing rate (percentage) from
aileron channel to itself. Values: -100~100. If the value is negative, it will
adjust the aileron operation in the negative direction. If the value is positive, it
will adjust the aileron operation in the positive direction. The default is
100
.
ELE
▶
AIL
: This parameter is used to set the mixing rate (percentage) from
elevator channel to aileron channel. Values: -100~100. If the value is negative,
it will adjust the aileron operation in the negative direction. If the value is
positive, it will adjust the aileron operation in the positive direction. The default
is
-100
.
AIL
▶
ELE
: This parameter is used to set the mixing rate (percentage) from
aileron channel to elevator channel. Values: -100~100. If the value is negative,
it will adjust the elevator operation in the negative direction. If the value is
positive, it will adjust the elevator operation in the positive direction. The
default is
100
.
ELE
▶
ELE
: This parameter is used to set the mixing rate (percentage) from
elevator channel to itself. Values: -100~100. If the value is negative, it will
adjust the elevator operation in the negative direction. If the value is positive,
it will adjust the elevator operation in the positive direction. The default is
100
.
CAUTION
: The delta mixing function can not be utilized when either the
V-tail or Flaperon mixing function are active.
V-tail Mixing [V-tail Mix]
Corresponding model type: airplane, V-tail
CH2
CH4
CH2 (ELEV): elevator
CH4 (RUDD): rudder