PROBLEM
Device is not powering up.
Device not arming.
Chirp every 45 seconds
External magnet not working.
No connector for external magnet.
DOOR PROP
PROBLEM
After arming and door is opened, the
device chirps 4 times then shuts off.
DOOR CHIME
PROBLEM
After arming and door is opened, the
device blinks red.
TROUBLESHOOTING
PROBABLE CAUSE
1) Battery not properly installed.
1) Magnet not aligned correctly.
2) Battery is dead.
3) Cylinder had wrong cam installed.
4) Cylinder microswitch lever broken.
5) Cylinder installed incorrectly.
Low battery
Device is not set for external magnet.
Weatherized device.
PROBABLE CAUSE
The device is setup as Door Chime.
PROBABLE CAUSE
The device is setup as Door Prop
ACTION
1) Remove battery and firmly reinstall.
1) Use magnet locator to install magnet.
See magnet handing.
2) Replace battery.
3) Requires standard Yale cam.
4) Microswitch needs to be replaced.
Remove PCB and return to Detex Repair.
5) Check cylinder installation. Make sure key
is turned counter-clockwise all the way to ON.
Install new battery.
Cut JP1 jumper. With battery connected,
short "Test mode" pins, listen for 5 chirps.
See RE-HANDING section.
Weatherized device can not be used with
external contact.
ACTION
Reset device, slide Switch A to the
OFF
position.
ACTION
Reset device, slide Switch A to the
O
N
position.