background image

Detex Corporation,  302 Detex Drive,  New Braunfels,  Texas  78130-3045

830-629-2900  /  800-729-3839  /  Fax 800-653-3839  /  Text photos only: 830-481-6433  /  INTERNET: www.detex.com

104889   March 18, 2020               C

104889   Page 1

For device installation videos,

scan code below or

go to www.detex.com/videos

Page

 2
 3
 4
 4-5
 5
 6
 6-7
 7-8
 8

Table of Contents

Parts breakdown view & part numbers.........................................................
Hardware list, Device preparation.................................................................

Switch selector positions, Door mounting procedure....................................

Wall mounting procedure, Multi-door & SK procedure..................................

Device installation (finish)..............................................................................
Key Stop installation, Optional accessories..................................................

Special notes & definitions, Magnet handing & re-handing, operations........
Change door prop timiing..............................................................................
Operations continued, Troubleshooting.........................................................

Dwg #: 105830

INSTALLATION INSTRUCTIONS FOR THE EAX-300 DOOR PROP / DOOR CHIME (EAX-300 / 300W / 300SK)

The Detex EAX-300 is designed for applications that require a door prop alarm device on secured doors. The alarm,
with approximately 100dB, will sound when someone attempts to keep the door open beyond the selected time.
The EAX-300, with it's smaller size makes it the choice for quick and easy installations on emergency exit and restricted doors.

For WARRANTY information,

scan code below or

go to www.detex.com/warranty

Should you have any Question/Problem with your Detex device please call Detex Technical Support from the

job site at 1-800-729-3839 and choose option 2 on our menu. Please do not return the product to the distributor.

Summary of Contents for EAX-300 Series

Page 1: ...nding operations Change door prop timiing Operations continued Troubleshooting Dwg 105830 INSTALLATION INSTRUCTIONS FOR THE EAX 300 DOOR PROP DOOR CHIME EAX 300 300W 300SK The Detex EAX 300 is designed for applications that require a door prop alarm device on secured doors The alarm with approximately 100dB will sound when someone attempts to keep the door open beyond the selected time The EAX 300...

Page 2: ...ver Lock Nut 2 Keys MS 1039S Mag Switch surface mount see STEP 8 PP 5567 9 Volt Battery 105828 1 S R Circuit Board Kit Standard PP 5374 46 4 x 3 4 Screw PPH 102715 Backplate 102665 Magnet Kit 102607 Magnet Locator 5 Locate this component for Step 7 Mortise Cylinder with standard Yale cam required sold separately 715 313 7 8 6 9 10 12 13 11 105837 1 S R Circuit Board Kit Weatherized 2 3 5 6 7 8 9 1...

Page 3: ... can be ordered from Detex p n ECL 1595 If 7 pin cylinder is used OBSERVE STATUS INDICATOR OFF Turn key CCW to UNLOCK cover Approximately 8 times STEP 1 REMOVE COVER FROM BACK PLATE STEPS 2 6 PREP DEVICE If Key Stop is required see OPTIONAL KEY STOP page 6 CORRECT A B 104889 Page 3 AR DP P N 100980 1 4 20 x 1 PPH MACHINE SCREW P N 103276 63 14 x 1 PPH TYPE AB SELF DRILLING THREAD FORMING P N PP 51...

Page 4: ...or Wall mounting SK go to step 7B Place Backplate and Magnet locator on door as shown below Mark Backplate and Magnet holes on door and frame mullion Remove Backplate and Magnet locator before drilling holes or or Install magnet and backplate or Table A Selector Switch Functions STATUS INDICATOR SWITCH B OFF No indication that device is armed or disarmed ON DP SWITCH A OFF Door chime mode ON Door ...

Page 5: ...0 feet must use twisted pair 2 1 16 slotted jeweler screwdriver required Disconnect power cut JP1 jumper Screw wires to P1 terminal block 18ga Max wire dia not available on weatherized Fitting or nut NOT included 1 2 connector P N PP 5107 Common Closed Mag Switch 1 Mag Switch 2 Remove 2 screws 8b Drill hole 8c Reassembly 8d SK Wire connections Applying a small amount of lube to threads will aid wh...

Page 6: ...ive times Step 3 With the door open install the device on the door Step 4 Turn the key CCW to the ON position The red LED blinks twice Step 5 Close the door or bring the external magnet into position with the external door switch The siren chirps and the LED flashes on the selected side of the device red LED flashes for the left side or external green LED flashes for right side The device will now...

Page 7: ...e 2 o clock position TROUBLESHOOTING If the unit does not arm the magnet may need to be re aligned or shimmed closer to the EAX 300 If the unit fails to operate correctly restart the device by removing the battery for approximately five seconds LOW BATTERY ALERT Simultaneous siren chirps and red LED flashes occur at 45 second intervals when battery reaches approximately 7 volts Cut the LV Opt jump...

Page 8: ...ery Cut JP1 jumper With battery connected short Test mode pins listen for 5 chirps See RE HANDING section Weatherized device can not be used with external contact ACTION Reset device slide Switch A to the OFF position ACTION Reset device slide Switch A to the ON position Step 4 Close then release the OKC switch lever to cycle to the next highest door prop time Table B lists the available door prop...