background image

Applications:

This interior application unit is designed for 

embassies and museums.

Product Features:

Materials and Finishes:

• Lid:

  

  choice of 12 standard colors selections. 

 

 

  Custom colors and Corian™ can be quoted

 

• Cabinet:  Our signature 304 stainless steel/    
 

Design & Construction:

• Designed for secure and reliable operation 

  

 
• Cabinet constructed of 304 stainless steel/

   

 
• 

 

 

 
• 

Dimensions:

• Height:
• Width:
• Depth:
• Arm Length:

Operation Features
6500 Series Control Head:

• 

 

  hydraulic shock suppression
• Hardened tool steel locking bars, cam and 

   

  roller assemblies
• Permanently lubricated bearings
• Your choice of manual or electronic control on 

 

  both directions
• Nearly universal integration to any number of   

  access control syst ems
• Your choice on each electronic direction of 

  

 

Options:

• Bi-directional key overrides
• 

 

  year lithium battery
• 

 

 
• 

 

 

  choices outside of our standard selection

• NEW!

   

  available
• Additional options available upon request

* Dimensions are approximate

The DS100-R Series 

Waist-High

DS100-R

Round End

 

|

 

Interior Application

Warranty:

defects in materials and 

one year from date of delivery. 

Input Voltage: 100-240 VAC

Input Current: 1.3 - .55 A

Frequency: 50/60 Hz

Storage Temperature: -40 to 158°F

Operating Temperature:  -4 to 131°F

Operating Voltage: 24VDC

Standards and Codes:

Austenitic stainless steel:

ASTM A240, A249, A276

Hot rolled steel:

AISI C-1020, AISI C-1018

All fasteners provided meet IFI ANSI/

ASME Fastener Standards

Standard D 1.1

The 6500 Series Control Head 

UL 294, UL 325, UL Subject 2593, 

CAN/ULC S319 & CSA C22.2#247

4008027

Our matching ADA gate 

(DS100-R-ADA with optional 

motorization) is available for 

DS100-R Series.

* Dimensions are subject to change without notice

 

512-321-4426 

INS-DS100R-190401 

Designed  Security,  Inc.  - 1402  Hawthorne  Street,  Bastrop  Texas  78602  - (800)  272-3555

 

[email protected] 

5

Electrical Specifications: 

Summary of Contents for DSI DS100-R

Page 1: ...is service manual after installation If an installation is done by a construction company or outside installer please pass this book along to the end user This book is required for maintenance troubleshooting repairs 512 321 4426 INS DS100R 190401 Designed Security Inc 1402 Hawthorne Street Bastrop Texas 78602 800 272 3555 sales dsigo com 1 ...

Page 2: ...ocated near the power supply along with the provided grounding wire from the power supply to ensure the equip ment is properly grounded Do not connect to a receptacle controlled by a switch Feature Level Destructive Attack Test I Line Security I Endurance IV Standby Power I ULC S319 Class 1 Wiring methods shall be in accordance with National Electrical Code ANSI NFPA 70 Canadian Electrical Code CS...

Page 3: ...king Bar Information 13 Hydraulic Shock Indexing 15 Electrical Introduction 16 Wiring Diagram 17 Wiring Legend 18 Logic Controller Settings 19 Testing Procedure 20 Limit Switch Limit Switch Cam Information 21 Maintenance Cleaning 22 Troubleshooting 23 Proper Turnstile Usage 26 Warranty 27 Appendix 512 321 4426 INS DS100R 190401 Designed Security Inc 1402 Hawthorne Street Bastrop Texas 78602 800 27...

Page 4: ...A DS100 R The DS100 R Series Waist High DS100 R Round End Interior Application Autumn Flurries Pewter Blue Jeans Lake Michigan Spanish Moss Concrete Obsidian Honey Oat Crushed Almond Peach Freeze Whole Wheat Standard top selections include Subject to availability Optional wood top upgrade shown with lights 512 321 4426 INS DS100R 190401 Designed Security Inc 1402 Hawthorne Street Bastrop Texas 786...

Page 5: ...ery choices outside of our standard selection NEW available Additional options available upon request Dimensions are approximate The DS100 R Series Waist High DS100 R Round End Interior Application Warranty defects in materials and one year from date of delivery Input Voltage 100 240 VAC Input Current 1 3 55 A Frequency 50 60 Hz Storage Temperature 40 to 158 F Operating Temperature 4 to 131 F Oper...

Page 6: ...ear hooks can be unlatched by pulling the lid from the back side forward then pivoting upwards in one motion Front Panel Removal panel needs to be removed This is accomplished by removing the two 10 32 phillips screws that connect the front panel to the cabinet located at the upper inside of the cabinet Step 1 Unlock Lid Step 2 Pull lid forward Step 3 Pivot up in back while pulling forward 512 321...

Page 7: ...ctronically controlled install grounded electrical outlet within the cabinet and ground the power supply to the cabinet frame with provided grounding wire diagram provided later in this manual Install arm assembly if applicable to the arm adapter utilizing the three 5 16 18 socket head cap screws We recommend applying removable strength blue thread sealant such as Loctite 243 to these screws Test ...

Page 8: ...ity of the engineer of record Installing product in oversized holes is not recommended Product will not set properly or achieve full designed load in oversized holes Setting torque only applies at the time of installation 4 Select a carbide drill bit with a diameter equal to the anchor diameter Drill hole at least 1 4 deeper than nominal anchor embedment Clean hole with pressurized air or vacuum t...

Page 9: ...ched in the case of an electronic two way control head In this instance each rotational per valid entry request Our anti backup cams are designed so that it is mechanically impossible to become trapped within the turnstile when properly installed recommendations Installation is simple connect inputs from access control devices into the logic controller and plug the unit s power supply into a 100 2...

Page 10: ...512 321 4426 INS DS100R 190401 Designed Security Inc 1402 Hawthorne Street Bastrop Texas 78602 800 272 3555 sales dsigo com 10 ...

Page 11: ...ies 6535 WH 427 430 T80 ADA 6541 439 448 P60 HD Control Head Bearings Indexing Springs 1106 Waist High Light 1108 Full Height Heavy 1107 ADA Extra Heavy Solenoid Springs 6510 Fail Open Spring 6016 Fail Lock Spring 6051 Solenoid Deltrol D4A53717 82 Hydraulic Shock Absorbers 6560 WH 427 430 T80 ADA 6561 439 448 P60 HD 0381 Locking Bar Casting w Oil Impregnated Bushings 6520 Index Pin Tubing L N V Ou...

Page 12: ...ering and exiting a facility Fail lock Upon power failure an electronically controlled direction would remain locked methods of exiting are available Unless equipped with key overrides this is can be easily converted to fail open by ordering alternate parts This is also known as fail secure Fail open Upon power failure an electronically controlled direction would remain open normal situations but ...

Page 13: ...sting These holes act as pivot points for the locking bar casting The inner holes are fail lock and outer holes are fail open A 5 dowel pin slides through the entire assembly to hold everything in place Alternate linkages and springs are needed to convert a direction s power failure status any key override equipped head to ensure everything is done correctly Direction 1 Solenoid Direction 2 Soleno...

Page 14: ...re diameter is 041 6518 Fail Lock Linkage These have an approximate length of 2 25 and also include an extra hole the key override option 6010 Fail Lock Solenoid Spring These look the same as the fail open but are actually lighter in force Wire diameter is 032 This spring was also used on the 6100 Series Control Head 0383 Fail Lock Locking Bar Assembly Includes locking bar casting w oil impregnate...

Page 15: ...al are facing upright Some models may require an additional turn or two outward if the arm does not self center on even the lowest setting 1 Hydraulic Shocks Setting Loosen the set screw on the head of the dial and turn the knob The dial can be set between 0 and 8 The higher the number the stronger the shock is Tightening the set screw can alter the shock strength so a good habit is to loosen the ...

Page 16: ...or inputs just like all previous generations so any installation is compatible in one way or another If assistance is needed with understanding how to convert the wiring from access control to the new logic controller please view this manual or call our technical support department for assistance I1 A B OK ESC I2 IB IC ID IE 01 02 03 04 XD10 Inputs To activate apply local 24VDC to desired input te...

Page 17: ...tion 2 Access Control Relay N O COM Direction 1 Override Relay N O COM Direction 2 Override Relay N O COM Black Black Brown Brown Blue Blue White not used White not used Optional Direction 1 LED Indicator Light Tri color day light visible Banner Engineering S18DLGRYPQ Optional Direction 2 LED Indicator Light Tri color day light visible Banner Engineering S18DLGRYPQ if fail lock if fail open if fai...

Page 18: ...t wire from light s cable Red Light An indicator to inform pedestrians that the unit is locked or that pedestrians require credentials to enter Uses brown output wire from light s cable As a side note indicator lights purchased from Designed Security Inc can also be wired to glow yellow If desired this can be used instead of red with the unused white wire on the light s cable to indicate to pedest...

Page 19: ...s home position which re engages the locking bar The cam is still free to move until it swings back to the home position Turnstile control heads use a triangular shaped limit switch cam One point of the triangle needs to be facing the index pin bar with two springs when the cam is in the home position The two indents in the sides of the triangle are for jigging purposes It does not matter which po...

Page 20: ...n inputs Toggle Direction 1 by pressing and Direction 2 by pressing This should be set to On in almost every installation number of access control requests the unit will allow in queue Each value can be set from between 1 for maximum security to 3 for fast paced passage The default is 2 The method to change these settings is the same as the Timer Values Screen This screen gives statistics about ho...

Page 21: ...ontrol either access control is not connected properly is normally closed instead of normally open or is access control system If the unit successful unlocks but does not re lock upon rotation try to manually trigger the appropriate limit switch for the direction that is not working correctly If this helps it is likely that the limit switch is not properly being triggered by the limit switch cam E...

Page 22: ...inless steel wax or polish Contrary to common belief stainless steel is not rust proof Exposure to certain chemicals and harsh environments such as ocean air or chemical plants may cause surface corrosion Minor discoloration can be removed with a rust penetrating product such as PB Blaster along with non scratching scouring pads Severe cases of contamination may require the use of specialty produc...

Page 23: ... wiring is correct try to disconnect the solenoids from outputs 01 04 If system stops cycling replace faulty solenoid Turnstile powers up but does not respond Improper wiring from access control to logic controller Ensure one leg of access control output relay is connected to 24VDC and the other to the desired input Access control device malfunction Disconnect access control from logic controller ...

Page 24: ... height and or tweak the triggers on the limit switch Refer to page for more information Turnstile only rotates 30 degrees Limit switches wired incorrectly Refer to pages 16 18 for wiring information and page for limit switch placement Limit switch cam is misaligned The top cam should have one point facing the control board If this is not the case readjust the top cam Refer to page for top cam inf...

Page 25: ...age 18 for direction port explanations Refer to page 12 for more information Additional parts will be required to convert operation The control head can be returned labor plus parts if required Please contact us before returning a control head in this instance sheet Turnstile fails lock when needed to fail open or vice versa Unable to hold direction open to allow multiple people to pass through th...

Page 26: ...rcing the user to back out of the turnstile There are timer settings for adjusting how long it takes for this to occur The default time provided is 7 seconds The reason for this is in case somebody swipes and walks away without passing through Walk at a reasonable pace through the turnstile Do not slam the rotor through the rotation This can be unsafe and may cause unnecessary wear and tear to the...

Page 27: ...s in material and workmanship when properly installed used and maintained according to instructions DSI will for a period of one 1 year three 3 years for Optical Turnstiles from date of purchase repair or replace any part which upon our examination prove to be defective under normal use DSI SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL LOSS OR DAMAGE ARISING OUT OF THE FAILU...

Reviews:

Related manuals for DSI DS100-R