6500 Series Control Head Electrical Information
Each electronic control head comes with a power supply, a programmable logic controller (PLC), limit
switches (or optionally, proximity sensors) and solenoids. For safety purposes, it is recommended that
you read all literature on the electrical components before attempting to install the control head into
a turnstile.
The 6500 Series Control Head is on the third generation of electronic components. The new XD10 logic
controller is a direct replacement of both the 0789 control board and 6789 (Keyence KV-16DR) logic
controller.
The latest enhancements provide a broader temperature range for outdoor installations (-4 to 131F)
as well as a user friendly text based interface with a daylight visible display. With this also comes
some new features such as on board testing buttons, turnstile statistics / information, etc.
with installed products. If an installation has the old 0789 circuit board (PCB) and has the optional
proximity sensor upgrade, new proximity sensors will need to be purchased. This is because the
0789 board had NPN inputs while the XD10 (and the KV-16DR) have PNP inputs.
The new PLC still requires relay contact closures for inputs just like all previous generations, so any
installation is compatible in one way or another. If assistance is needed with understanding how
to convert the wiring from access control to the new logic controller, please view this manual or
call our technical support department for assistance.
I1
A
B
OK
ESC
I2 IB IC ID IE
+
+
–
–
01
02
03
04
XD10
Inputs
To activate, apply local 24VDC + to desired input terminal.
Full Height Models:
Dir 1 - Clockwise
Dir 2 - Counter Clockwise
+
24
VDC
-
24
VDC
I1
Dir 1
Input
I2
Dir 2
Input
IB
Dir 1
OR
IC
Dir 2
OR
ID
Dir 1
Limit
IE
Dir 2
Limit
Waist High Models:
Dir 1 - Right Hand
Dir 2 - Left Hand
Outputs
Dir 1 Fail Lock
Dir 1 Green Light
01
Dir 1 Fail Open
Dir 1 Red Light
02
Dir 2 Fail Lock
Dir 2 Green Light
03
Dir 2 Fail Open
Dir 2 Red Light
04
XD10 Logic Controller
0740
KV-16DR Logic Controller
6789
Control Board
0789
Lower Row Ports:
To 24VDC- | Lim 1 Inp | Lim 2 Inp | Unused | Unused | Fire Alarm Inp
Upper Row Ports:
Dir 1 Inp | Dir 2 Inp | Dir 1 OR Inp | Dir 2 OR Inp | Unused
Connect access control relays to 24VDC+ and desired input
Upper Row Ports:
Unused | Dir 1 Sol | Dir 2 Sol | Dir 1 Lt Red | Dir 1 Lt Green
Lower Row Ports:
24VDC+ | 24VDC- | Rly Com | Rly Com | Dir 2 Lt Red | Dir 2 Lt Green
Dir 1 = CW on FH, RH on WH/ADA | Dir 2 = CCW on FH, LH on WH/ADA