STEP 2.
Remove 4 screws used on center case cover and pull it away from device to access the
mount plate screws (2). Remove 2 screws used on end cap in order to access the end bracket
mounting screws (2). Although the surface finish is strong and durable, handle the parts with
care to avoid scratches or contamination from harsh chemicals during the service process.
STEP 3.
Remove 2 screws on end bracket and slide it away from device, then remove 2 screws
on mount plate while holding the device horizontally and against door to keep it engaged after
removing all screws.
Center Case Cover
Mount Plate
End Bracket
End Cap
(4x) 6-
32 x 3/8” PFHUMS
DTX #100162-106 FOR SS
(MULTIPLE FINISHES AVAILABLE)
(2x) ¼-20x1.0
” P
PH DTX #100980, or
(2x) #14 x 1.0” PPH
SELF DRILLING #103276-63, or
(2x)
#14 x 1.25” PPH
WD SCREW #PP-5183-110
(2x) 10-
32 x 5/16” PFHUMS
DTX #101632-2 FOR SS
(MULTIPLE FINISHES AVAILABLE)
(2x) ¼-
20 x 1/4” PPHMS
DTX #101621-5
(2x) ¼-
20 x 1/4” PPHMS
DTX #101621-5
(2x) ¼-
20x1.0” PPH DTX #100980, or
(2x) #14 x 1.0” PPH SELF DRILLING #103276
-63, or
(2x) #14 x 1.25” PPH WD SCREW #PP
-5183-110