1
Signal Strength Metal ID
2
Ground Phase Level
3
Mineralization Gauge
4
Battery & Volume Gauge
5
Message Window
6
Menu Columns
7
Metal ID
8
Metal ID Meter
A
Built-in Speaker
B
Wireless Headphone Switch
C
Backlight Switch
D
Higher Volume
E
Lower Volume
F
+/-
G
Ground Balance
M
Menu Scroll
P
Pinpointing
CONTROLER
A
B
C
D
E
F
G
M
P
1
2
3
4
5
6
7
8
Physical Buttons
•
The built-in mini size speaker’s volume(A) and headphones volume can be adjusted by
press the volume control buttons(D,E). one click per level. keep pressing to change
the level. the gauge on screen will change also with each press.
•
To turn on wireless headphones, press button(B) on the quest once to turn on, press
again to turn off. The symbol on the screen will flash if not paired with headphone,
press power button on headphone set to power on and pair one time. The speaker will
mute once wireless audio transferring function been activated(B) or wire headphone is
connected. Once the quest and headphones are paired they stay paired.
•
You can switch on the backlight(C) for low light condition. It will reduce the battery life
slightly.
•
M (M) button. Press the button once to power on, Press 1 second to power off, Once on
use power button M to scroll through the menu, Use up and down arrows to scroll
through each menu item.
•
▲
▼
(F)buttons. Increase , decrease.
•
(G) for ground balancing. pump coil while pressing auto ground balancing
button.
•
(P)for pinpointing. Use to indicate exact position of buried target. start by holding
coil away from target whilst holding pin point button in. Target will be indicated in the
centre of the coil when the sound is greatest.
Menu
•
Two digit (8) real-time metal I.D. readout, depth, programs selected and other data.
•
Modes available . all metal(ALL METAL) or discrimination(DISC).
•
Gain : increases or decreases detectors sensitivity.
•
Threshold : or Hum Level, from -9 to + 9 amplifies the signal ID filter.
•
ID Filter : or discrimination level
•
Manual G.C.
Activates the Ground Balance adjustment to compensate for
different types of soil.
•
Audio Tone. Choice of 6.
•
Frequency Shift :from F1 to F7
•
Ground Phase (2) display the recent ground cancellation level
•
Mineralization Gauge(3) :ground mineralization level
•
Battery gauge(4): 4 segments is full charged, 1 segment is low battery lever with less
than 30% power capacity.
•
Volume gauge(4). 4 segment is maximum, empty is mute.
•
Signal arrows(1): display the target metal I.D. and strength of the target signal. 3 arrows
is maximum and close to the ground surface. 1 arrow is small size target or deep
buried.
•
Message window(5): Overload information or other indication.
Summary of Contents for Quest Pro
Page 1: ...deteknix Quest Pro ...