IMPORTANT WARNINGS 

GENERAL 

 

 

Before  using  the  device  read  this 
manual carefully. Keep it just in case of 
necessity. 
 

  Abide all the rules and precautions stated in the 

manual. Follow all the instructions one by one. 

  Keep the devices away from water and moisture 

 

CONDITIONS 

Do  not  energize  the  device  above  or  below  the  given 
limits of extreme hot or cold conditions, 

 

Temperature:    

Between 0

C and +55

    Relative Moisture:   %0- 95 concentrated 

SERVICE 

In case of any malfunction or below conditions contact 
with your authorized service,  
 

  When Mains cable or the plug is harmed,  

  Contact of device with a fluid,  

  Exposure of rain and water,  

  Fell down of device or harmed outer cover,  

  Serious performance fall on the device,  

  Depending on the instructions stated in manual, if 

your device not working properly, further usage or 
possible wrong usage may cause other 
malfunctions. Contact with your authorized service 
in such terms.  

INFORMATION RELATING TO USAGE ERRORS 

Do not allow to change the opening or setting up your 
device by unauthorized persons. As a result of such a 
situation,  your  device  can  start  working  differently 
compared to the first case. 

 

SECURITY CHECK 

Please  ask  your  dealer  to  check  that  the  service  is 
working properly and safe conditions. 

 

 

 

TO  BE  CONSIDERED  AND  CONSUMER  CAN  DO 
TO MAINTAIN, REPAIR AND CLEANING 

-  Do  not  attempt  to  repair  the  device  yourself, 

because  if  you  open  the  oven  door  or  tampering 
can be exposed to possible electric shock or cause 
a malfunction of the device. 

-  If  a  fault  occurs,  please  contact  your  dealer  or 

authorized 

service 

center. 

Device 

technical 

intervention  must  be  carried  out  by  authorized 
service personnel qualified. 

-  The  device  should  be  cleaned  with  a  damp  cloth. 

Never spray, polish, do not use any chemicals such 
as detergents. 

-  Alcohol,  thinner,  cologne,  sprays,  lighter  too 

intense,  pungent  cleaning  agents  do  not  mislead 
the  device  to  false  alarms  and  may  cause 
deterioration  of  the  detector.  In  addition,  gas 
detection holes must be clean and dry. 

 

 

TRANSPORTATION 

Device  must  be  carefully  transported  avoiding  all 
physical  bump,  stroke  and  possible  fluid  entry. 
Malfunctions that caused by improper transportation is 
not under warranty. 

 

 

 

 

 

 

 

Model 

TSD-701 

Supply Voltage 
Type 
IP Rating 
Compatible Standard 

12-24 VDC  

IPX2D 
TS EN 50194-1 

Contact Output 

1 pcs, NC or  NO 

Startup Time 

3 minutes 

Normal Condition Led Color 

Green 

Error Condition Led Color 

Yellow 

Alarm Condition Led Color 

Red 

Alarm Level (Natural gas) 

%10 LEL 

Output Relay 

30 V DC, 50mA 

Alarm Output 
 
Alarm Buzzer Sound Level 

Solid State Relay + 
Voice and flashing leds 
85 dB  

NO 

NC 

Summary of Contents for TSD-701

Page 1: ...CURITY CHECK Please ask your dealer to check that the service is working properly and safe conditions TO BE CONSIDERED AND CONSUMER CAN DO TO MAINTAIN REPAIR AND CLEANING Do not attempt to repair the device yourself because if you open the oven door or tampering can be exposed to possible electric shock or cause a malfunction of the device If a fault occurs please contact your dealer or authorized...

Page 2: ...uld be a likely place to be the most accumulation of gas The detector will NOT be over direct cooked meals sink and toilet bowl which should be at least 1 5 meters away The detector will NOT be adjacent Aspirator fan and ventilation which should be at least 1 5 meters away 3 Remove the head of the detector attached to base by turning it counter clock wise until you reach the short line on the base...

Page 3: ...ted due to TS EN 50194 1 criteria Detector stops alarm condition and turns normal operating mode when gas density is decreased 4 If the gas test is applied frequently it shorten the life of detector reduces the sensitivity 5 Detector that passed the test can be integrated to the system NOTES ON USING OF DETECTOR TSD 701 series detectors must be used for detecting the type of gas which is written o...

Page 4: ...rrent Alarm Current Operation Temperature C Startup Time Dimensio ns mm Body Material TSD 701 10 LEL NC NO 12 24 VDC 12 VDC 100mA 100mA 24 VDC 50mA 50mA 10 55 3 Mins Ø110 h50 White Color ABS MANUFACTURER Bilgi Elektronik San Ve Tic A Ş Address Dudullu Organize Sanayi Bölgesi 1 Cadde İsmet Tarman İş Merkezi No 1 Kat 2 No 32 Ümraniye İstanbul Tel 90 216 455 88 46 Fax 90 216 455 99 06 www bilgielektr...

Reviews: