VET-330WH Owner’s Manual 

SETUP AND INSTALLATION, CONT. 

Desk Mounting 

1. 

The location chosen should be a stable, level surface (either a desk or solid table),  
free of temperature extremes and water. The display should be where it can be easily 
viewed, not subjected to direct sunlight, and where the keypad is within easy reach of 
the operator. 

2. 

Place the display in the bracket and install the included enclosure knobs. Adjust the 
angle of the display for the best viewing, and then completely tighten the knobs. Refer to 
the image for Step 5 in the Wall Mounting instructions on the previous page. 

 

AC Power Adapter 

To apply power to the scale using the 
supplied 120 to 230V AC 15V DC 300 mA 
wall plug-in UL/CUL listed AC power 
adapter (Cardinal P/N 6800-1044), insert 
the plug from the power adapter cable 
into the power jack on the right side of the 
display (as viewed facing the display) and 
then plug AC power adapter into the 
proper electrical outlet. The scale is now 
ready for operation.  
 

Battery Pack 

The VET-330WH scale uses a 7.2V DC, 1200 mA built-in rechargeable battery pack 
(Cardinal P/N 6800-1067). The VET-330WH can operate for approximately 8 hours of 
continuous use with a fully charged battery pack. 
 

Low Battery Indicator 

When the battery pack needs to be recharged, a low battery indicator on the 
display will turn on. If the battery voltage drops too low for accurate weighing, 
the scale will automatically shut off and you will be unable to turn it back on. 

 

Battery Charging 

When the low battery indicator is displayed, the operator should plug the AC power adapter 
into the scale display and then into the proper electrical wall outlet. To fully recharge the 
battery pack, the AC power adapter must be connected for approximately 14 hours. Note 
that the VET-330WH can still be operated while the battery pack is charging. Also, note that 
charging the battery pack for more than 14 hours 

will not

 damage it. 

 

NOTE:

 If the AC power adapter is disconnected before the 14 hours, the scale will continue 

to charge the battery pack when the AC power adapter is plugged back in.  
 
 
 

AC Power 
Adapter Plug 

AC Power Adapter

Summary of Contents for VET330WH

Page 1: ...I MODEL VET 330WH Digital Veterinary and General Purpose Scale Owner s Manual...

Page 2: ...II...

Page 3: ...st such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever meas...

Page 4: ...1961 M045 O1 Rev B y VET 330WH Owner s Manual II...

Page 5: ...4 Desk Mounting Page 5 AC Power Adapter Page 5 Battery Pack Page 5 Low Battery Indicator Page 5 Battery Charging Page 5 DISPLAY SYMBOLS Page 6 KEY FUNCTIONS Page 7 OPERATION Page 8 CONFIGURATION Page...

Page 6: ......

Page 7: ...i Blade input wall plug in UL CUL listed AC power adapter Cardinal P N 6800 1044 Construction Stainless steel Tare 100 of scale capacity Keys HOLD UNIT ON ZERO OFF TARE Operating Environment Temperatu...

Page 8: ...l from the scale platform display and other components You should have the following components 1 Scale Platform with attached Display 1 Stainless Steel Platform Cover 1 Wall or Desk Display Mounting...

Page 9: ...knees until you re in a squatting position Never bend at the waist with your legs straight Lifting Scale from Floor to Transport Position 1 Stand close to the scale with your feet 8 to 12 inches apar...

Page 10: ...2 13 64 in 5 mm holes in the wall for the mounting wall anchors Use the mounting bracket as a template to mark holes to drill 3 Insert the wall anchors in the wall until they are flush with the wall 4...

Page 11: ...et The scale is now ready for operation Battery Pack The VET 330WH scale uses a 7 2V DC 1200 mA built in rechargeable battery pack Cardinal P N 6800 1067 The VET 330WH can operate for approximately 8...

Page 12: ...the weight display is at center of zero This symbol is turned on to indicate the battery pack needs to be recharged HOLD The arrow symbol is turned on and will flash after pressing the HOLD key to in...

Page 13: ...guration Mode press this key to select the menu ON ZERO OFF 1 When the scale is off press and release this key to turn the scale on 2 If the scale is already on press and release this to turn the scal...

Page 14: ...lay Place the container e g a box pet carrier or travel cage on the scale platform allow the scale to stabilize and then press the TARE key The weight on the scale can be tared zeroed off until the fu...

Page 15: ...ss the UNIT key to toggle between Enable display will change to 0 or Disable display will change to 4 Press the HOLD key The display will change to 0 5 Proceed to Automatic Shutoff To select lb pounds...

Page 16: ...should not require changing in most locations If the factory settings do not meet the requirements of your location contact the factory for the value for your location With 9 enable from the function...

Page 17: ...capacity Remove the weight to clear the error This error can also be displayed if the Zero count is too high Please consult your scale service representative CARE AND MAINTENANCE The heart of the VET...

Page 18: ...ng for the freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does...

Page 19: ...ction with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or con...

Page 20: ...30WH Owner s Manual 14 Cardinal Scale Manufacturing Co 102 E Daugherty Webb City MO 64870 USA Ph 417 673 4631 or 1 800 641 2008 Fax 417 673 2153 Technical Support 1 866 254 8261 E mail tech cardet com...

Reviews: