8525-0377-0M Rev A 

x

 8432-CH Owner’s 

AC POWER ADAPTER 

To power the scale using the optional 110-240V AC 50/60 Hz 12V DC wall plug-in AC power 
adapter, connect the small round plug from the AC adapter into the power jack on the back of 
the indicator and then plug the AC power adapter into the proper electrical outlet. Refer to 
Figure 1. On models requiring 240V AC, it is the customer’s responsibility to obtain the 
correct AC power adapter plug. 
 
 

BATTERY OPERATION 

Batteries 

The scale can use 6 "AA" size Alkaline, Ni-Cad or NiMH batteries (

not included

). You must 

first obtain and install batteries before operations can begin. Batteries are contained in a 
battery holder inside indicator. Access is via a removable panel on the back of indicator. 
 
When using batteries, all 6 batteries must be of the same type. They must be all Alkaline, 
Ni-Cad or all NiMH. In addition, 

DO NOT

 mix Ni-Cad or NiMH batteries. 

 

IMPORTANT!

 The scale can be operated from Alkaline, Ni-Cad or NiMH batteries. 

All six (6) batteries must be of the same type. They must all be Alkaline, all Ni-Cad 
or all NiMH. 

DO NOT

 mix Alkaline and Ni-Cad or NiMH batteries. 

 

CAUTION!

 The AC power adapter is also used to recharge the batteries, when the 

scale is operated from Ni-Cad or NiMH batteries. 

DO NOT

 connect the AC power 

adapter if using alkaline batteries. Also, when using alkaline batteries, make sure 
the 

0-3

 setup option is disabled (set to 0). Refer to Setup and Calibration or 

Setup Review sections of 750 Weight Indicator Owner’s Manual (8555-M483-O1). 

 

Battery Status 

The 750 indicator will operate for up to 250 hours on new Alkaline batteries or for up to 100 
hours on fully charged Ni-Cad or NiMH batteries depending on the condition of the batteries 
(from new to about 500 recharges). The battery bar graph on the display indicates the battery 
capacity in 4 steps: 
 

4 segments - the full battery capacity is available, 
3 segments - the battery is at 75% of capacity, 
2 segments - the battery is at 50% of capacity, 
1 segment: - the battery is at 25% capacity. 
 

When the battery voltage drops too low for accurate weighing, the indicator will show 

!6;

 

and then shut off. You will be unable to turn the indicator back on until the Alkaline batteries 
have been replaced or if using Ni-Cad or NiMH batteries, the AC power adapter is connected 
to the display to operate it and recharge the batteries. 
 

Battery Charging 

To recharge the Ni-Cad or NiMH batteries, the AC power adapter must be connected to a 
power outlet and plugged into the indicator. It will take approximately 8 to 10 hours to fully 
recharge the batteries in the display. Charging the batteries for more than 10 hours 

will not

 

damage them. 

NOTE:

 The indicator may be operated while the batteries are charging. 

 

Summary of Contents for 8432-CH-AC

Page 1: ...8525 M316 O1 Rev B x 8435 Owner s 1 Model 8432 CH PEDIATRIC SCALE with Inclined Chair Seat Owner s Manual...

Page 2: ...8525 M316 O1 Rev B x 8435 Owner s 2...

Page 3: ...posal This is in accordance with EU Directive 2002 96 EC Within North America the device should be disposed of in accordance with the local laws regarding the disposal of waste electrical and electron...

Page 4: ...240V AC 50 60Hz 12V DC 1A wall plug in UL CSA listed AC power adapter Cardinal part number 6800 1045 Models are available with the AC adapter included Keyboard Membrane type with 5 keys and 4 directi...

Page 5: ...Figure 1 ensuring that the narrow side of the column faces the scale platform Figure 1 Insert column onto scale base 2 Using a Phillips screwdriver install the eight screws and washers to secure the...

Page 6: ...ng a small flat blade screwdriver tighten the screws on both sides of the scale cable connector Next install the indicator on the scale column bracket by placing the screw heads on the back of the ind...

Page 7: ...C323 08 Gimbal for 8432 CH Child Seat 4 6021 1423 1 4 20 X 1 2 Truss Head Screws 4 6021 1553 10 24 X 1 2 Truss Head Screws 1 Remove child seat and hardware kit plastic bag with screws from box 2 Remo...

Page 8: ...ach the gimbal to the scale platform with the four 1 4 20 x 1 2 screws 6 Using the Philips screw driver tighten the screws 7 After the gimbal is installed position the child seat in the gimbal and att...

Page 9: ...T connect the AC power adapter if using alkaline batteries Also when using alkaline batteries make sure the 0 3 setup option is disabled set to 0 Refer to Setup and Calibration or Setup Review section...

Page 10: ...es proceed to step 7 If replacing the batteries remove all 6 batteries from the battery holder and then proceed to step 7 7 Install the 6 new AA size batteries in the battery holder noting the polarit...

Page 11: ...show a stable center of zero 0 weight condition Zero Weight Display with Item on Scale 1 Place the item blanket or similar covering in the child seat 2 The display will show the weight of the item in...

Page 12: ...8525 0377 0M Rev A x 8432 CH Owner s 10...

Page 13: ...1 REPLACEMENT PART IDENTIFICATION Item Qty Part Number Description 1 1 0033 0532 0A TOP PLATE ASSY 2 1 0033 0533 0A PLATFORM ASSY 3 1 0033 0534 0A LOAD CELL ASSY 4 1 0033 0546 08 BASE FEET 1 750 DIGIT...

Page 14: ...r the freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not i...

Page 15: ...n with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or contrac...

Page 16: ...8432 CH Owner s 14 Cardinal Scale Manufacturing Co 102 E Daugherty Webb City MO 64870 USA Ph 417 673 4631 or 1 800 641 2008 Fax 417 673 2153 Technical Support 1 866 254 8261 E mail tech cardet com 852...

Reviews: