AC CRUISE-100 v2.4 (04/2021)
Page 7
2) Seawater inlet
Seawater inlet valve
Ø
The strainer should be placed as low as possible beneath the waterline so that it does
not draw in any air. It should be placed far from the discards.
Ø
Pierce the hull with a Ø 21mm hole saw.
Ø
The streaks of the strainer must be placed towards the front of the boat to allow the
water to naturally enter by scooping during navigation.
Ø
Seal the junction with the hull properly using polyurethane sealant or Sicaflex. Do not
forget to paint the submerged part with special underwater paint.
Ø
The hull valve must remain accessible for maintenance operations.
Ø
Seal the valve/strainer and valve/hose connections with Loctite 577.
Cartridge prefilter
Ø
The prefilter must also be installed beneath the waterline to ensure a better
yield/output. It must be easy to access.
Ø
The fixing bracket is reversible to allow you to adjust the installation height.
Ø
Piping connections must be made with Tricoflex Ø 12 mm (inside diameter), for the
entire seawater system as well as the pressurized rinsing system.
§
Do not forget to fasten 2 stainless steel collars on each fitting.
Ø
Allow a minimum of 3 cm below the filter body for the clearance of the tank when
opening it. A screw is provided for screwing / unscrewing it.
Seawater position:
For use in desalinization
mode
Fresh water position:
For manual rinsing or
sterilization when needed
(
see Appendix A3
)
Closed position:
For changing the filter
cartridge (
see Appendix A4
)