AC CRUISE-100 v2.4 (04/2021)
Page 26
Appendix A4: Instructions for the Sterilizing Cartridge
With the watermaker OFF:
Ø
Close the seawater inlet valve.
Ø
Open the sterilizing cartridge:
be careful not to lose the O-ring
.
Ø
Remove the top screen.
Ø
Place the foam at the bottom of the filter.
Ø
Pour the sterilizing powder into the cartridge.
Ø
Replace the top screen and close the cartridge.
Ø
Check that the seal is correctly in place.
Ø
Remove the 5-micron cartridge from the prefilter.
Ø
Replace it with the sterilizing cartridge
Ø
Turn the rinsing valve to the fresh water position (see
Appendix A3
) so that the
sterilizing powder mixes with the water, the valve must be closed before all of the
powder disappears (there must be a little left inside the bowl).
Ø
Please note that this procedure is very quick. The watermaker should not be turned on
Ø
Duration of sterilization: 6 months maximum (to be repeated beyond that)
➥
Important
: Before the next start-up, rinse the system out using fresh water for 10 minutes.
Remove the ST2 sterilizing cartridge and replace it with a 5-micron cartridge.
WARNING!
The ST2 cartridge can be reused.
Remove the 5-micron
cartridge from the prefilter
Replace the 5-micron
cartridge with the ST2
sterilizing cartridge