background image

                                                                                                                   

 

This Manual is applicable to the  De Sisti F10 Vari-White 

 

Revised on July 2018 

ILT ITALY srl 

Via Cancelliera, 10/a  
00041 Albano Laziale (Rome) Italy 
tel. +39 06-902901 fax +39 06-90231051 
www.desisti.it 

 

7.

 

LOCAL MENU 

The SUPER LED F10 VW has a GRAPHIC DISPLAY backlit, with two local knobs, each one having a push/click function in addition to the rotation: 

 

 

KNOB 1

 

 

It  is  as  a  DEFAULT  the  CCT  Variation  Knob,  By  rotating  it  clockwise  the  CCT 
Changes from 2.750°K up to 6.900 °K. If such a knob is kept pushed, it provides 
a FAST ACTION on the KNOB 2 which is normally the DIMMING 

 

Display

 

It is a Graphic, backlit LCD Display. It contains all the relevant information for the product 

setup and performances, such as CCT, DMX Address, DMX Level, LED Temperature and 
local dimming. 

When the local knobs are not used for more than 5 seconds the display 

back illumination will go OFF and the display itself will go in STAND BY Mode. It will go 
ON again anytime a KNOB is activated. 

 

KNOB 2

 

It is as a DEFAULT the DIMMING Variation Knob, By rotating it clockwise the Dimming of 
the  Light Changes from 0up to Full Light Output. If such a knob is pushed, it has the 
selection or enter function to, for instance, enter into a Menu

DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE: 

The following are the BASIC FUNCTIONS and COMMANDS that are provided on the LOCAL MENU of the LED FRESNEL. The unit is provided with a USER 
MENU accessible instantly on the product. 

 

 
 

 

 

 

 

 
 

 
 

 

 

 

 

 

 

 

 

 

 

DMX ADDRESS 

This Function is to SET the 

DMX address

 from 

1

 to 512 

The Product is delivered with a default setting of the DMX address at 1. 

As indicated next to each picture, it is required to reach the DMX 
addr Menu, select the preferred base DMX Address and Select 
it. 

Once the DMX Address is SET, in order to return to the MAIN 
MENU, it is necessary to rotate KNOB 2 counter-clock-wise to 
return to the EXIT item and then select it by pressing KNOB 2 
itself. 

 

1st menu displayed 

2nd menu displayed 

Explanation of each menu function 

Summary of Contents for SUPER LED F10 VW

Page 1: ...ht using a LED ARRAY combined with the DE SISTI Patented optical system to optimize the photometric performances of LED ARRAYS when utilized in combination with either Fresnels or Plano Convex lenses The Lighting Fixture is DMX Controlled and includes a number of parameters that can be set locally it is equipped with power supply for AC universal feed 90 240V 50 60Hz and feature variable CCT from ...

Page 2: ...and DMX DAISY CHAIN In fact each Fixture is respectively equipped with For DMX 1 XLR5 pin Panel Mount Male DMX IN 1 XLR5 pin Panel Mount Female DMX OUT For Mains Supply 1 20A Powercon NAC3MPA BLUE POWER IN 1 1 20A Powercon NAC3MPB WHITE POWER OUT It is recommended to Daisy Chain a Max of 10 fixtures even if the limitations imposed by DMX Standards are for an higher q ty of units and even if the Po...

Page 3: ...ens diameter 250 mm Size of barndoor ring Seat Diameter Ring Diameter 314 mm 313 mm Specifications subjectto change withoutnotice 5 SAFETY INSTRUCTIONS Professional use This luminaire has been designed for professional use and must be operated by qualified personnel only Not for residential use Grounding WARNING THIS LUMINAIRE MUST BE GROUNDED Electrical connections IMPORTANT The cores in this mai...

Page 4: ...procedure should be adopted Before connecting the luminaire to the electrical mains ensure that A Earth line is present on the power socket B The mains voltage is within the rated range of the luminaire see technical data on the rating label C The front safety shield is present and in good condition It consists of a Fresnel lens made by borosilicate un toughened glass with a Diameter 150 mm thickn...

Page 5: ...l go in STAND BY Mode It will go ON again anytime a KNOB is activated KNOB 2 It is as a DEFAULT the DIMMING Variation Knob By rotating it clockwise the Dimming of the Light Changes from 0up to Full Light Output If such a knob is pushed it has the selection or enter function to for instance enter into a Menu DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE The following are the...

Page 6: ...d FOCUSED locally and its dimming plus CCT level can be blocked so that for instance a system lighting a SET can be operated by a remote switch or simple brakers by TURNING POWER ON The machine is set to Auto save OFF as default in this condition the Fixture can be controlled locally until a DMX device is connected to it Once the Console will be acting it will take priority over any local control ...

Page 7: ...fax 39 06 90231051 www desisti it INFORMATION PROVIDED ON THE DISPLAY 8 DIMENSIONS Dimensions Black mm Red inches Dimensions Black mm Red inches Display of Correlated Colour Temperature Display of LED Case TEMPERATURE Display of DMX LEVEL DMX Address Display of local Potenciometer Level when in local control or turned off DMX controller Graphic Scale of Dimming ...

Page 8: ...D with Isopropyl alcohol 3 Clean the lenses with a soft damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX control cable proper conditions 10 SAFETY STANDARDS Europe The product conforms the Applicable European Directives Standards Low Voltage Directive 73 23 EEC as amended by 93 68 EEC EMC Directive 89 33...