This Manual is applicable to the De Sisti F10 Vari-White
Revised on July 2018
ILT ITALY srl
Via Cancelliera, 10/a
00041 Albano Laziale (Rome) Italy
tel. +39 06-902901 fax +39 06-90231051
www.desisti.it
Working conditions
Working Position
Lighting fixture: max. tilting ±90° from horizontal
Ambient temperature, ta at the place of installation and storage
Minimum 10°C, m40°C
Humidity at the place of installation and storage
25-80% (not condensing)
Minimum distances from inflammable surfaces
Top
Back
Sides
Front
0,2 m.
0,1 m.
0,1 m.
0,75 m.
The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above table are the minimum distances
recommended. Other requirements for safe use are:
A.
Do not cover the apertures of the luminaire housing. They are essential for correct ventilation
B.
Use only original accessories and spares from De Sisti Lighting.
C.
Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the luminaire weight.
D.
In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting.
E.
A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension point and the eyelet
at the front of the body
WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE.
6.
INSTALLATION INSTRUCTIONS
The following procedure should be adopted:
Before connecting the luminaire to the electrical mains ensure that:
A.
Earth line is present on the power socket.
B.
The mains voltage is within the rated range of the luminaire (see technical data on the rating label)
C.
The front safety shield is present and in good condition. It consists of a Fresnel lens made by borosilicate un-toughened glass, with a
Diameter = 150 mm , thickness = 5 mm type ( 3 min )
WARNINGS :
•
Do not operate the product if the ambient temperature exceeds 40° C
•
Provide a minimum clearance of 0,1m (4 in.) around fans and air vents.
•
Shields, lenses safety or dichroic glasses shall be changed if they have become visibly damaged to such an extent that their effectiveness
is impaired, for example by cracks or deep scratches.
•
The luminaire shall only be used complete with its protective shield
D. Applying power: never connect to dimmer power. Install a power plug on the power cable using the following pin assigment:
1 : Neutral
2 : Live
Green/Yellow : Ground - This fixture must be connected to ground.
Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power on.
E. Stand Alone operation:
Using the navigation buttons and display readout ( refer to the “Local Menu” chapter )navigate to Manual and set the desired intensity (for
additional operations see “Local Menu” chapter)
F. DMX operation:
Connect DMX cable.
Navigate to Address mode (Addr) and set the desired address, (refer to the “Local Menu” chapter). Connect to DMX controller (refer to the “Channel
Setting” in the “Local Menu” chapter) and Use it.