background image

                                                                                                                   

 

This Manual is applicable to the  De Sisti F10 Vari-White 

 

Revised on July 2018 

ILT ITALY srl 

Via Cancelliera, 10/a  
00041 Albano Laziale (Rome) Italy 
tel. +39 06-902901 fax +39 06-90231051 
www.desisti.it 

 

Working conditions 

Working Position 

Lighting fixture: max. tilting ±90° from horizontal 

Ambient temperature, ta at the place of installation and storage

 

Minimum 10°C, m40°C

 

Humidity at the place of installation and storage 

25-80% (not condensing) 

Minimum distances from inflammable surfaces 

Top 

Back 

Sides 

Front 

0,2 m. 

0,1 m. 

0,1 m. 

0,75 m. 

The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above table are the minimum distances 
recommended. Other requirements for safe use are: 
 
A.

 

Do not cover the apertures of the luminaire housing. They are essential for correct ventilation 

B.

 

Use only original accessories and spares from De Sisti Lighting. 

C.

 

Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the luminaire weight. 

D.

 

In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. 

E.

 

A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension point and the eyelet 

at the front of the body 
 

WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE. 

6.

 

INSTALLATION INSTRUCTIONS

 

The following procedure should be adopted: 
Before connecting the luminaire to the electrical mains ensure that: 

A.

 

Earth line is present on the power socket. 

B.

 

The mains voltage is within the rated range of the luminaire (see technical data on the rating label) 

C.

 

The front safety shield is present and in good condition. It consists of a Fresnel lens made by borosilicate un-toughened glass, with a 
Diameter = 150 mm , thickness = 5 mm type ( 3 min ) 
 

WARNINGS : 

 

 

Do not operate the product if the ambient temperature exceeds 40° C 

 

Provide a minimum clearance of 0,1m (4 in.) around fans and air vents. 

 

Shields, lenses safety or dichroic glasses shall be changed if they have become visibly damaged to such an extent that their effectiveness 
is impaired, for example by cracks or deep scratches. 

 

The luminaire shall only be used complete with its protective shield 
 

D.  Applying power: never connect to dimmer power. Install a power plug on the power cable using the following pin assigment: 

1 : Neutral 

 

2 : Live 

Green/Yellow : Ground - This fixture must be connected to ground. 

Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power on. 

E.  Stand Alone operation:  
Using the navigation buttons and display readout ( refer to the “Local Menu” chapter )navigate to Manual and set the desired intensity (for 
additional operations see “Local Menu” chapter) 

F.  DMX operation:  
Connect DMX cable.  
Navigate to Address mode (Addr) and set the desired address, (refer to the “Local Menu” chapter). Connect to DMX controller (refer to the “Channel 
Setting” in the “Local Menu” chapter) and Use it.

 

Summary of Contents for SUPER LED F10 VW

Page 1: ...ht using a LED ARRAY combined with the DE SISTI Patented optical system to optimize the photometric performances of LED ARRAYS when utilized in combination with either Fresnels or Plano Convex lenses The Lighting Fixture is DMX Controlled and includes a number of parameters that can be set locally it is equipped with power supply for AC universal feed 90 240V 50 60Hz and feature variable CCT from ...

Page 2: ...and DMX DAISY CHAIN In fact each Fixture is respectively equipped with For DMX 1 XLR5 pin Panel Mount Male DMX IN 1 XLR5 pin Panel Mount Female DMX OUT For Mains Supply 1 20A Powercon NAC3MPA BLUE POWER IN 1 1 20A Powercon NAC3MPB WHITE POWER OUT It is recommended to Daisy Chain a Max of 10 fixtures even if the limitations imposed by DMX Standards are for an higher q ty of units and even if the Po...

Page 3: ...ens diameter 250 mm Size of barndoor ring Seat Diameter Ring Diameter 314 mm 313 mm Specifications subjectto change withoutnotice 5 SAFETY INSTRUCTIONS Professional use This luminaire has been designed for professional use and must be operated by qualified personnel only Not for residential use Grounding WARNING THIS LUMINAIRE MUST BE GROUNDED Electrical connections IMPORTANT The cores in this mai...

Page 4: ...procedure should be adopted Before connecting the luminaire to the electrical mains ensure that A Earth line is present on the power socket B The mains voltage is within the rated range of the luminaire see technical data on the rating label C The front safety shield is present and in good condition It consists of a Fresnel lens made by borosilicate un toughened glass with a Diameter 150 mm thickn...

Page 5: ...l go in STAND BY Mode It will go ON again anytime a KNOB is activated KNOB 2 It is as a DEFAULT the DIMMING Variation Knob By rotating it clockwise the Dimming of the Light Changes from 0up to Full Light Output If such a knob is pushed it has the selection or enter function to for instance enter into a Menu DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE The following are the...

Page 6: ...d FOCUSED locally and its dimming plus CCT level can be blocked so that for instance a system lighting a SET can be operated by a remote switch or simple brakers by TURNING POWER ON The machine is set to Auto save OFF as default in this condition the Fixture can be controlled locally until a DMX device is connected to it Once the Console will be acting it will take priority over any local control ...

Page 7: ...fax 39 06 90231051 www desisti it INFORMATION PROVIDED ON THE DISPLAY 8 DIMENSIONS Dimensions Black mm Red inches Dimensions Black mm Red inches Display of Correlated Colour Temperature Display of LED Case TEMPERATURE Display of DMX LEVEL DMX Address Display of local Potenciometer Level when in local control or turned off DMX controller Graphic Scale of Dimming ...

Page 8: ...D with Isopropyl alcohol 3 Clean the lenses with a soft damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX control cable proper conditions 10 SAFETY STANDARDS Europe The product conforms the Applicable European Directives Standards Low Voltage Directive 73 23 EEC as amended by 93 68 EEC EMC Directive 89 33...

Reviews: