background image

One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

StatguardFlooring.com

TB-9057

 Page 1 of 6

© 2020 DESCO INDUSTRIES INC

Employee Owned

Digital Surface Resistance Meter Kit

Installation, Operation and Maintenance

Description

The Statguard Flooring 

D19290

 Digital Surface 

Resistance Meter Kit is an instrument designed to 

measure resistance point-to-point (Rtt) or surface to 

ground (Rtg).
Its test functions include:

•  Resistance measurement accuracy of ±10% 

(±20% accuracy for 1 x 10

12

 ohms and greater)

•  Resistance range of <1 x 10

3

 ohms to >1 x 10

12

 

ohms

•  Under load voltages of 10 and 100 volts ±5%

•  Electrification period of approximately 15 seconds
The Digital Surface Resistance Meter also measures 

ambient temperature and relative humidity. Up to 100 

measurements may be stored and recalled from the 

meter's internal memory. This includes the resistance 

value, temperature, relative humidity and test voltage at 

the time of the measurement.

November 2020

The Surface Resistance Meter is referenced and 

designed to be used to make measurements in 

accordance with the test procedures in: 
•  Compliance Verification - ESD TR53 - Resistance  

Measurements

•  Worksurfaces - ANSI/ESD S4.1 Worksurfaces

•  Floors - ANSI/ESD S7.1- Resistive Characterization 

of Materials Floor Materials

•  Foot Grounders - ESD SP9.2 - Foot Grounders 

Resistive Characterization

•  Garments - ANSI/ESD STM2.1 Garments 

Seating - ANSI/ESD STM12.1- Seating - Resistive 

Measurement

•  Floor/Footwear - ANSI/ESD STM97.1 - Floor 

Materials and Footwear- Resistance Measurement 

in Combination with a Person

“A Compliance Verification Plan shall be established 

to ensure the Organization’s fulfillment of the technical 

requirements of the ESD Control Program Plan. Process 

monitoring (measurements) shall be conducted in 

accordance with a Compliance Verification Plan that 

identifies the technical requirements to be verified, the 

measurement limits and the frequency at which those 

verifications shall occur. The Compliance Verification 

Plan shall document the test methods and equipment 

used for process monitoring and measurements. If the 

test methods used by the Organization differ from any 

of the standards referenced in this document, then 

there must be a tailoring statement that is documented 

as part of the ESD Control Program Plan. Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements. The test equipment selected shall be 

capable of making the measurements defined in the 

Compliance Verification Plan.” (ANSI/ESD S20.20 

section 7.3)
The Digital Surface Resistance Meter and its 

accessories are available with the following:

Packaging

D19290 Digital Surface Resistance Meter Kit

1  Digital Surface Resistance Meter

2  Test Leads, 5' Length

2  5 lbs. Electrodes

1  Electrode Spacer, 10"

1  Electrode Spacer, 36"

4  AA Alkaline Batteries

1  Ground Plug Adapter

1  Gator Clip

25  Measurement Location Labels

1  Plastic Carrying Case

1  Certificate of Calibration

Made in the

United States of America

Figure 1. Statguard Flooring Digital Surface 

Resistance Meter Kit

TECHNICAL BULLETIN TB-9057

Summary of Contents for Statguard Flooring D19290

Page 1: ...STM97 1 Floor Materials and Footwear Resistance Measurement in Combination with a Person A Compliance Verification Plan shall be established to ensure the Organization s fulfillment of the technical requirements of the ESD Control Program Plan Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verifi...

Page 2: ...O INDUSTRIES INC Employee Owned Features and Components Digital Surface Resistance Meter Figure 3 Statguard Flooring D19290 Digital Surface Resistance Meter Figure 2 Statguard Flooring D19290 Digital Surface Resistance Meter Kit Figure 4 Digital Surface Resistance Meter features and components C B D E E G F A ...

Page 3: ...ings and Memory Recall menus to exit and return to the home screen G Battery Compartment Open this compartment to install the four AA alkaline batteries needed to power the meter Replace the batteries once the battery icon on the display is empty Home Test Results Screen H J L I K Figure 5 Home Test Results screen H Battery Life Indicator Displays the approximate life of the meter s 4 AA alkaline ...

Page 4: ...ctrode placements include Most commonly used area of a surface Most worn area Center of surface Furthest area from a grounded point If the surface to be measured has sections i e floor tiles garment panels place the 5 pound electrodes on different sections for Rtt measurements Clean the material s surface for test lab measurements but do not clean the surface for materials that are already install...

Page 5: ...5 pound electrodes and place the electrodes on the most commonly used area of the surface Use the 10 electrode spacer to space them 10 apart from each other The electrodes should also be 2 away from any edge and 3 away from any grounded point If the most used area is not obvious use two points near the center of the surface 4 Push the red pushbutton to perform a measurement Should the 15 second el...

Page 6: ...n cleaning instructions Per ANSI ESD S4 1 Worksurfaces The test specimens and electrodes shall be cleaned twice with a minimum 70 isopropanol water solution using a clean low linting cloth each time Note The item should then be conditioned for 72 hours minimum Figure 13 Measuring the Resistance Point to Point Rtt of floor materials Specifications Resistance Ranges 1 x 103 to 1 x 106 ohms 10 Volts ...

Reviews: