Note 1: Use mechanical switch or photo 

coupler or relay for external input. If 
the grounding potential of external 
device to use for external input and 
the grounding potential of this 
product use are different, the 
external device used for external 
input should have an insulated 
on/off procedure for the 0V line. 

 

  Be sure to carry out the grounding procedure (according to the class D procedure).  

  Check that the Frame of the Machine is grounded. If it is not grounded, be sure to follow the grounding class 

D procedure. When you contact it with this product, connect 0V (black) and the grounding point of the power 
supply and signal cable to being common. But when 0V and the grounding point are not connected to be 
common, do not connect 0V line to the grounding point.  And when you use an optional AC adapter, this 
product does not need to be properly grounded. 

 

Air Piping: 

  Use clean dry compressed air to deliver the ionized air. 

 

Attach an air tube (with an outside diameter of Φ6 mm) to the air inlet of the Ionizer.

 

  Connect the air tube via the regulator to the air supply (Air compressor). 

  Supply cleaned air (not containing water or oil) to the Ionizer. 

 
 
 

6.  Operation: 

 

 

Caution 

 

Always use air when supplying power to the ionizer. Otherwise, the ozone concentrations inside the Ionizer will 
increase due to electric discharge, which may cause detrimental effect on the main body and its surroundings. 

 

1.  Install the equipment at a designated place, and perform power supply wiring, grounding wiring, and air 

piping.  

2.  Supply DC24V through the power source connector of the equipment. The power source of high voltage 

starts and corona discharge is generated at the discharge electrode, producing air ions. When the power 
source is activated, the green LED (in the normal condition) is on.  

3.  Open the main valve of the air equipment (installed by your company), and supply air to the nozzle with 

designated pressure after adjusting the Air pressure. Ionized air is blown out from the nozzle and static 
electricity of the charged objects placed in the air-flow is neutralized and removed. Pay attention to 
excessive air pressure, which will lower the effect of removing electricity. (See the table under "Air Pressure 
Working Range" under "4. Specifications" for the working range of air pressure.  

4.  When you attach the tube to the nozzle, move the tip of the tube closer to the charged object and blow ion 

air. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SCS 966-II

Page 1: ...losion proof Type Do not use this unit at a location or an atmosphere in which combustible gas or solvent is handled or else ignition or explosion may occur A high voltage is applied to the discharge needle Do not allow any conductive material including your finger any part of your body wire or any tool to get close to the needle or an electrical shock accident or a malfunction of the Unit may occ...

Page 2: ...for use with this product always use a power supply that has been certified by an EU Notified Body as a Limited Power Source as defined in IEC EN60950 1 or IEC EN61010 1 or optional AC adapter Use only the power supply and signal cable included with the product to connect this product to the power supply Install this product in accordance with the installation and wiring instructions described in ...

Page 3: ...stop signal HV OFF input Discharge OFF Short circuited to 0V Discharge ON Open Residual voltage 0 5V or less Ozone 0 05 ppm or less Measured Distance 300mm Ion balance 15 V or less Material Enclosure ABS Cover Stainless Discharge needle Tungsten Accessories Instruction manual Power supply and signal cable Caution label English 2 1 The applicable pressure range depends on the nozzle to be used Chec...

Page 4: ...affected by exposure to ozone Installation Install it at a designated place by using fixing holes 3 φ3 4 The 966 II does not work well in a vertical position Please always mount it horizontal or pointing down Tightening torque on housing to the main body should be 20 N cm or less Wiring Attach wire to power supply and signal cable as follows Color Signal Name I O Description Red DC 24V Power suppl...

Page 5: ...o the air supply Air compressor Supply cleaned air not containing water or oil to the Ionizer 6 Operation Caution Always use air when supplying power to the ionizer Otherwise the ozone concentrations inside the Ionizer will increase due to electric discharge which may cause detrimental effect on the main body and its surroundings 1 Install the equipment at a designated place and perform power supp...

Page 6: ...ent is recommended after 20 000 hours If regular maintenance is not performed the life span of the 966 II will decrease The maintenance is very important Position the unit at a place where it is free from water and oil etc It gets wet dry it with a clean cloth Attachment of contamination to the tip of the discharge needle will deteriorate the static and elimination effect If deterioration of the s...

Page 7: ... Check the housing of the discharge needle to confirm that it is correctly installed and securely locked Short circuited Check that the discharge needle is free from conductive materials Internal circuit is broken Turn off the power and then turn the power back on Cleaning Check indicator C C Lights up Dirt on discharge needle C C indicator remains lit even after the discharge needle has been clea...

Page 8: ...plied After turning the Ionizer OFF wait 1 second or more before turning it ON again Do not use power supply and signal cable provided with the products for a moving section Otherwise they may break down Avoid scratching the cords of the sensor switch lead wires etc Letting the cords be subject to scratching excessive bending pulling rolling up or being placed under heavy objects or squeezed betwe...