background image

TB-3043

 Page 6 of 6

© 2019 DESCO INDUSTRIES INC

Employee Owned

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

Figure 7.  Shorting the ionizer’s fan grill with a metal 

probe to test the alarm

Specifications

The comparative efficiency of benchtop ionizers is 

determined by a standard test published by the ESD 

Association: ANSI/ESD STM 3.1.  Typical positive and 

negative discharge times (1000V - 100V) measured 

using this standard are shown in Figures 5 and 6.  The 

performance of the ionizer was measured with the unit 

positioned as shown, with the fan speed on high and without 

a filter.

Input Voltage and 

Frequency

Internally selectable for

100-120 VAC, 50/60 Hz or

220-230 VAC, 50/60 Hz

Power Consumption

12 W

Dimensions 

(including stand)

9.5" H x 6.0" W x 3.1" D

(241 mm x 152 mm x 79 mm)

Weight

4.5 lbs (2.0 kg)

Balance (Offset 

Voltage) at 12"

±3 V typical

±25 V maximum

Neutralization 

(Discharge) Time at 12"

< 2 seconds

Airflow

Three-speed fan

50-100 CFM

Emitter Points

.050" diameter tungsten

Ion Emission

Steady-state DC with sense 

feedback

Fuse

250 mA slow blow

High Voltage Power 

Supply

5.5 kVDC nominal

Ozone

<0.05 ppm

Enclosure

Powder coated aluminum

Country of Origin

United States of America

Accessories

60509 IONIZER MOTION SENSOR

Desco offers the 

60509

 Desco Ionizer Motion Sensor as 

an accessory for the High Output Benchtop Ionizer.  Use 

it to activate the ionizer when an operator is present and 

deactivate it when the workstation is vacant.  The Ionizer 

Motion Sensor conserves energy and reduces ionizer 

maintenance.

Figure 8.  Desco 

60509

 Ionizer Motion Sensor

Limited Warranty, Warranty Exclusions, Limit 

of Liability and RMA Request Instructions

See the Desco Warranty - 

Desco.com/Limited-Warranty.aspx

Summary of Contents for 60506

Page 1: ...rrounding air When an electrostatic charge is present on objects in the work environment it will be neutralized by attracting opposite polarity charges from the ionized air Note that ionization systems should not be used as a primary means of charge control on conductors or people Reference EN 61340 5 2 1 clause 5 2 9 September 2019 The primary method of static charge control is direct connection ...

Page 2: ...nit OFF and unplug the power cord A B C E D Figure 2 High Output Benchtop Ionizer features and components A Power Cord Connection Connect the power cord here B Power Switch Toggle the switch to the left to turn the ionizer OFF Toggle the switch to the right to turn the ionizer ON C Fan Speed Switch Toggle the switch to the left to set the fan speed to Low Toggle the switch to the middle to set the...

Page 3: ...will continuously sound The user must then reset the unit by turning it OFF and back ON WARNING RISK OF ELECTRIC SHOCK THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY DO NOT PERFORM ANY SERVICING OF INTERNAL PARTS UNLESS YOU ARE QUALIFIED TO DO SO NOTE The AC power cord MUST always be disconnected before the unit is disassembled The input voltage may be verified or reset by re...

Page 4: ...ments recorded in a factory ambient environment Per ANSI ESD S20 20 the test method for Product Qualification test is ANSI ESD STM3 1 and for Compliance Verification is ESD TR53 which advises Measurements should be made at the location where ESD sensitive items are to be ionized A larger area may require additional ionizers Per S20 20 the required limit for ionizer discharge time is user defined U...

Page 5: ... the data can justify lengthening the calibration period If ionizers require adjustment the calibration period should be shortened Although ESD TR53 does not advise a test frequency JESDD625 A Revision of EIA 625 recommends ionizers be tested semiannually noting to use S3 1 except the number of measurement points and locations may be selected based on the application NOTE A charged plate analyzer ...

Page 6: ... W Dimensions including stand 9 5 H x 6 0 W x 3 1 D 241 mm x 152 mm x 79 mm Weight 4 5 lbs 2 0 kg Balance Offset Voltage at 12 3 V typical 25 V maximum Neutralization Discharge Time at 12 2 seconds Airflow Three speed fan 50 100 CFM Emitter Points 050 diameter tungsten Ion Emission Steady state DC with sense feedback Fuse 250 mA slow blow High Voltage Power Supply 5 5 kVDC nominal Ozone 0 05 ppm E...

Page 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Desco 60505 60507 ...

Reviews: